Updated:2026-11-28
Views: DB14/T 1966-2019 judges whether a textile carries fluorescent whitening agents by looking at it under a 254 nm or 365 nm UV lamp. It sets out five routes to that judgement: direct, water extraction, perspiration, water immersion and rubbing. The routes differ; the viewing conditions do not. This page walks through the clauses, then sets out where the LEAC-280L dual-wavelength handheld lamp sits in each one, how to position it, and how to word the result.
DB14/T 1966-2019 is a Shanxi provincial standard covering the qualitative determination of fluorescent whitening agents in fibres and textile products. The whole method rests on one physical fact: a fluorescent whitening agent absorbs UV and re-emits in the visible range. The instrument requirement is therefore modest, but the conditions around it are strict.
Clause 4 lists the hardware in two groups. The lamp: 254 nm or 365 nm, with a device that protects the eyes. The environment: a darkened room and an inspection table, with an operator who is not colour blind and has been trained. The rest is bench equipment - a 100 cm steel rule, a 0.1 g balance, a water bath at 37 ± 2 °C, a 250 mL glass-stoppered reaction bottle, a G1 sintered-glass funnel, and distilled or grade 3 water to GB/T 6682.
Then look at the viewing steps in 5.1.2 and 5.2.2. All five methods use the same template:
Switch the lamp on, select 254 nm or 365 nm, and let it warm up for 1 min.
Turn off the room lighting and close the curtains.
Clean the lamp table.
Place the specimen - or the colorimetric tube, adjacent fabric, rubbing cloth - on the table and record what it does.
Those four steps make the real requirement clear. The question is not whether a lab owns a UV lamp. It is whether the lab can produce 254 and 365 nm reliably, hold a dark field, protect the operator's eyes, and keep the table clean. Miss any one of the four and the reading cannot be repeated by the next operator.
The LEAC-280L is a dual-wavelength handheld lamp: one 8 W 365 nm tube and one 8 W 254 nm tube, 16 W in total, in a horizontal body of 337 × 83 × 64 mm at about 1 kg. Quartz tubes sit behind a pure UV filter and an aluminium reflector; the lamp runs from a 24 V adapter, or from an internal lithium battery in the battery version. Against the clauses:
| Clause requirement | LEAC-280L | What to watch in practice |
|---|---|---|
| 4.2, 254 nm or 365 nm | One 8 W tube at each wavelength, separate switches | The two bands cannot run together; use 365 nm for fluorescence, then switch to 254 nm for a cross-check |
| 4.2, eye protection | LUV-10 UV goggles supplied as standard | Mandatory for 254 nm; switch on to view, off immediately after |
| 4.3, inspection table | Horizontal body sits flat on the bench; an optional stand fixes it as a stationary source | The lit window is about 260 × 50 mm, so large specimens are swept in strips |
| 5.1.2, 1 min warm-up | Quartz tubes are unstable from cold and need the same minute | The opening specimen of the day is where an early reading goes wrong |
| 4.3, darkened room | The lamp provides excitation, not darkness | Ceiling light, window light and a phone screen all wash out weak fluorescence |
| Power | 24 V adapter, or internal lithium battery | The battery version works in a darkroom or a mill with no socket nearby |
The restriction on running both bands deserves a note. It comes from the power and thermal design of the lamp, and it also keeps two spectra from overlapping in the same view. In practice the sequence is simple: 365 nm for brightness and shape, then 254 nm as a second look. Same specimen, same bench, same lamp - no swapping and no borrowing. That matters on a disputed sample, because changing lamps usually means changing distance and angle, and the reading conditions have already moved.
The second point is the difference between body length and lit window. The body is 337 mm long, but the light leaves through a filter of roughly 260 × 50 mm. A 40 × 40 cm specimen cannot be covered in one pass. Work in 5 cm strips with 2-3 cm of overlap between them, and the seams will not hide anything. A steady horizontal sweep gives more even coverage than circling the lamp over the surface.
Specifications, power options and the accessory list are on the LEAC-280L dual-wavelength handheld UV lamp page.
Three preparation details are easy to skip: wear clean plastic or latex gloves with no fluorescence of their own; fold small pieces and cut large ones to a representative 40 × 40 cm; spread about 50 g of fibre by the multi-point method, or about 10 g of yarn.
Positioning matters more than the lamp here. Lay the specimen flat on a matte black inspection surface. White paper or white cloth is a poor choice: paper and cotton often carry optical brightener themselves, the whole background lights up, and weak fluorescence on the specimen disappears into it. Hold the lamp 10-15 cm away at about 45°, so the beam does not reflect straight back off the surface. Kill the lights, close the curtains, and give the eyes 5-10 seconds to adapt before reading. Then switch to 254 nm and look again. Viewing the same specimen at both bands is a practical way to separate real fluorescence from a bright spot created by violet reflection: a genuine emitter changes in brightness and shape when the band changes, while plain reflection does not.
Wording is covered in section 5: no fluorescence outside a few isolated fibres is recorded as "no fluorescent whitening agent"; fluorescence is recorded as "the specimen may contain fluorescent whitening agent".
Cut the specimen into roughly 5 × 5 mm pieces, or 10 mm lengths for fibre and yarn, and mix. Weigh 1 g ± 0.1 g into a 250 mL stoppered bottle, add 100 mL grade 3 water, and hold at 37 ± 2 °C for at least 6 h. Filter through the G1 sintered-glass funnel, pressing the residue, and let the filtrate cool to room temperature. Take 25 mL into a colorimetric tube and prepare a blank of the same volume of water.
The target changes from a solid to a liquid, and so does the geometry. Stand the two tubes side by side and light them from the side and slightly in front; the question is whether the sample tube fluoresces more than the blank. Lighting from directly above puts a reflection on the meniscus that hides the effect, and reading the sample tube without a blank makes a faint scatter look like a result. 365 nm reads this step directly; 254 nm serves as confirmation.
In these three methods the lamp is not the difficult part - the adjacent fabric is. The specimen and the standard adjacent fabric are treated and separated to GB/T 3922-2013, GB/T 5713-2013 and GB/T 3920-2008 respectively, and the adjacent fabric goes under the lamp to see whether brightener has migrated across. For rubbing, run 20 cycles dry and 20 wet, then read the dry and wet cloths separately and record them separately.
Clause 4.3 is explicit: use single-fibre adjacent fabric, and the reagents, adjacent fabric and sewing thread must show no fluorescence under UV. So before each run, scan the blank adjacent fabric with the lamp and confirm it is clean. That is both a compliance step and the day's reference point. These pieces are small enough for the 260 × 50 mm window to cover in one pass.
Eyes. 254 nm is hard on the cornea and skin. Wear UV goggles, keep a hand on the switch, and turn the lamp off when not viewing. In a darkroom used for long periods, ventilate; whether a given short-wave tube is ozone-free depends on the tube, so check the specification.
Darkness. Curtains and ceiling lights are the obvious part. What gets missed is cleaning the table: fibres, paper dust and marker writing from the previous run all glow, and the next specimen inherits a false positive.
Contamination. Detergent is the usual culprit. Gloves, workwear and cloths washed in a powder containing optical brightener are strong emitters in their own right, and they will light up the specimen in the operator's hand. Use non-fluorescent gloves, single use, and keep cuffs away from the sample.
The standard gives a qualitative result, and the wording has to follow it: no fluorescence is recorded as "no fluorescent whitening agent", fluorescence as "the specimen may contain fluorescent whitening agent". It should not be written as "detected" or as a percentage. The method has no quantitative capability and does not confirm identity, so a quantitative statement goes beyond its scope.
A report should carry the standard number and the method used (the five methods do not substitute for one another), a description of the sample (fibre type, colour, whether bleached), the viewing conditions (254 nm or 365 nm, and whether both bands were used), and the date and operator. The sample description matters: bleached cotton may carry brightener left from processing, and that has to be discussed separately from contamination that arrived with the raw material.
Yes. Clause 4.2 reads "254 nm or 365 nm", so either band satisfies the text. A dual-band lamp is steadier in practice, because 365 nm shows brightness and shape while 254 nm provides a cross-check against violet reflection. There is no need to replace a single-band lamp that works; add the second band when disputed samples start to appear.
Not on the LEAC-280L. The switches are separate, but the power and thermal design allows one band at a time. The working sequence is to scan and record under 365 nm, switch off, then look again under 254 nm, with both observations going into the raw record.
A quartz tube is unstable from cold and can sit below its rated output for the opening tens of seconds. Clauses 5.1.2 and 5.2.2 require a 1 min warm-up. Starting early on the opening specimen of the day is how weak fluorescence gets recorded as absent, and the error repeats across all five methods.
It is better avoided. Paper and cotton often contain optical brightener, so the background glows on its own and raises the level against which the specimen is judged. Use a matte black surface, or a dark matte board, to keep the contrast.
No, as long as the sweep is complete. Work in 5 cm strips in one direction with 2-3 cm of overlap, then turn 90° and sweep again to catch elongated contaminants that sit across the strips. Covering the whole area in one pass is not required; incomplete coverage is what changes the conclusion.
Yes. The LEAC-280L is supplied either with a 24 V adapter or with an internal lithium battery, and the battery version suits a mill floor or a temporary darkroom. It still needs the 1 min warm-up, and output falls as the cell drains, so a charge check before the shift belongs in the work instruction.
No. The standard gives a qualitative judgement, and "detected" implies confirmation and quantification that the method does not provide. The correct wording is "the specimen may contain fluorescent whitening agent". Confirming a specific compound needs instrumental analysis and falls outside this standard.
This page follows the clause order of DB14/T 1966-2019; the official text governs. Other uses of UV inspection - leak detection and foreign-fibre screening - are collected under fluorescent inspection. The dual-band lamp used here is the LEAC-280L; single-band 365 nm handheld lamps are in the 365 nm UV lamp range.
Email: info@xinysun.com
Tel: +86-131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447
SiteMap | Privacy Policy | FAQ
