Xinysun Instrument (Shanghai) Co., Ltd.

Products

PRODUCTS

Breadcrumb: Home > Products > Life Science Instruments

Life Science Instruments

Authorized distributor for LUYOR (USA) and UVP (USA). Life science instruments target molecular biology and laboratory research, featuring UV crosslinkers (254 nm rapid crosslinking for DNA/RNA membrane transfer fixation, bacterial and phage inactivation, PCR contamination control) and supporting UV fluorescence detection equipment, for universities, research institutes and biopharma labs. In stock in Shanghai with selection and technical support.

How Life Science Instruments Divide the Work: Excitation, Crosslinking, Irradiation, and Observation

The four types of equipment in this line are often lumped together, but their roles are actually clear-cut: fluorescent protein flashlights handle excitation and observation (viewing GFP and DsRed); UV crosslinkers deliver a quantified dose of energy (nucleic acid membrane crosslinking, PCR decontamination); irradiation systems handle controlled light experiments (photocatalysis, phototoxicity, optogenetics); and UV lamps and transilluminators handle benchtop illumination and gel observation. First identify which category your experiment falls into, then compare chamber size, wavelength, and temperature control.

Category What It Solves Representative Models
GFP Fluorescence Flashlight In vivo fluorescent protein observation, transgenic screening LUYOR-3415RG, 3280, 3124RB, NIGHTSEA Xite
Laboratory Irradiation System Photocatalysis, phototoxicity, optogenetics, and photochemical synthesis LUYOR-3550, 3450, 3480, 3419PMA, 3486
UV Crosslinker Nucleic acid membrane crosslinking, PCR decontamination, and UV mutagenesis LUYOR UCL-3200, UCL-3500, XEPU-1208, 1215
Laboratory UV Lamp Gel illumination, fluorescence observation, photocatalysis, and benchtop disinfection LUYOR-3405A, 3109, LELMS-38L, B-100AP
UV Transilluminator Gel observation and gel excision/recovery LUV-260, XEPU-1126ML, LUV-450

The comparisons above are compiled from publicly available specifications on the individual product pages. For specific configurations, prices, and lead times, please refer to the corresponding product page or call the number at the bottom of the page. Xinysun Instruments (Shanghai) Co., Ltd. supplies LUYOR and XEPU instruments for industrial inspection, UV curing and speed measurement.

Four Types of Equipment, Four Different 'Light Tasks'

Light equipment in life science labs is often lumped together, but the division of labor is clear: fluorescent protein flashlights handle excitation and observation, answering 'is it expressed?'; UV crosslinkers deliver a quantified dose, answering 'is crosslinking sufficient?'; irradiation systems handle controlled light experiments, answering 'what happens at a set dose?'; and UV lamps and transilluminators handle benchtop illumination and gel observation, answering 'where are the bands?'.

Once the tasks are clearly separated, selection stays on track: if you need to see, buy a light source with a matching wavelength and filter glasses; if you need a dose, buy a chamber instrument with an energy mode and sensor; if you need long irradiation times, prioritize temperature control and uniformity over brightness.

How to Choose: Work Backwards from Your Experimental Goal

1. Start by defining the experimental goal: observing expression, fixing nucleic acids, light treatment, or viewing gels - the four goals correspond to four types of equipment and are not interchangeable.

2. Then set the wavelength: 440-460nm for GFP, 510-540nm for DsRed; 254nm for membrane crosslinking; typically 365nm for photocatalysis; 302nm for gel viewing and 365nm for gel excision.

3. Next consider sample format and throughput: a single dish, a 96-well plate, a whole tray of plants, or hybridization tubes will determine the chamber and irradiation area.

4. Finally, consider documentation needs: if dose and temperature must go into a paper's methods section, an energy mode and temperature control are mandatory.

Experimental Goal vs. Equipment at a Glance

Look up your goal in this table to avoid buying the wrong type.

Experimental GoalEquipmentKey Specifications
Viewing GFP / DsRed expressionFluorescent protein excitation light source + filter glassesWavelength match, irradiation area, battery life
Fixing nucleic acids to a membraneUV Crosslinker254nm, energy mode, chamber size
Phototoxicity, photocatalysis, optogeneticsIrradiation SystemWavelength, dose, chamber temperature
Gel observation and excisionUV Transilluminator302/365nm, benchtop uniformity, protective shield
Benchtop disinfection, localized irradiationLaboratory UV LampWavelength, intensity, and whether ozone is produced

Common Applications

Transgenic screening in plants and animals: primary screening of fluorescent proteins to narrow the scope of subsequent PCR validation.

Molecular hybridization: post-transfer crosslinking and fixation, which determine signal strength and background.

Cellular phototoxicity assessment: standardized assays such as 3T3 NRU, where dose and temperature must be reproducible.

Photocatalysis and photosynthesis: conditional screening and catalyst evaluation.

Nucleic acid electrophoresis: gel viewing, gel excision and recovery, and gel image archiving.

Cleanliness and decontamination: PCR pre-treatment, and disinfection of clean benches and biological safety cabinets.

Further Reading

Selection and Brands: UV Crosslinker FAQ: Uses, Selection, Differences from an Oven, and Operating Workflow, How to Choose a UV Irradiance Meter: Principles, Units, Three Models Compared, and Periodic Verification Methods, Avoiding Pitfalls in Choosing Fluorescent Protein Excitation Sources: Why Do Many Experiments Show No Fluorescence Signal?, How to Choose Between a Blue-Light Transilluminator and a UV Transilluminator? Dye Compatibility and Protection for 470nm Gel Excision, How to Choose a Wavelength for a UV Crosslinker: 254/312/365nm Applications and Models...

Frequently Asked Questions

What is the simplest setup for fluorescent protein observation?

A dual-wavelength excitation light source plus a matching pair of filter glasses is all you need to start. The LUYOR-3415RG switches between RB (440-460nm, for GFP) and GR (510-540nm, for DsRed) with no darkroom required. To view a whole tray of plants or a group of animals at once, switch to the 3124RB hanging model or the 3280 high-power flashlight.

Can a UV crosslinker and a UV transilluminator replace each other?

No. A crosslinker is a closed chamber that delivers a quantified dose at 254nm, so the dose is reproducible for validation. A transilluminator is an open benchtop device that transmits light from below, used for observation and gel excision. Using a transilluminator for a few minutes to crosslink a membrane gives an uncontrolled dose, poor reproducibility, and a methodology that cannot be clearly described.

Do these instruments have to be used in a darkroom?

No. For fluorescence observation, simply dimming the ambient light provides adequate contrast. Irradiation and crosslinking instruments are either closed chambers or directional light sources and do not depend on a darkroom. A darkroom is truly needed only for quantitative fluorescence imaging and weak-signal detection, and a light hood or dark box can serve as a substitute.

For a newly established lab, what is the minimum workable setup?

Equip for the three most common tasks: viewing fluorescence (a dual-wavelength excitation light source plus matching glasses), running gels (a transilluminator, with dual 302/365nm wavelengths being the most convenient), and decontamination and crosslinking (a UV crosslinker). These three cover most routine needs; purchase an irradiation system separately when you have a specific light-experiment requirement.

Can a single instrument serve multiple purposes?

Some can: a dual-wavelength crosslinker covers 254 and 365nm, a dual-wavelength transilluminator handles both gel viewing and excision, and a triple-wavelength UV lamp covers 254/302/365nm in one unit. However, 'versatility' usually means the intensity at each wavelength is lower than that of a dedicated model. If one wavelength is your main workhorse, a dedicated instrument is still recommended.

What are the facility requirements for these instruments?

UV instruments require ventilation and light shielding, and 254nm tubes need attention to ozone. Irradiation and crosslinking equipment need space for heat dissipation; excessively high ambient temperatures can defeat chamber temperature control. Transilluminators need a stable benchtop and a nearby power outlet. When space is tight, prioritize separating 'observation' instruments from 'irradiation' instruments to avoid mutual interference.

What does routine maintenance involve?

Three things: clean the optical windows and filters (fingerprints and dust directly reduce signal), record cumulative lamp hours (replace before the rated life rather than waiting for failure), and regularly verify intensity (with an irradiance meter or the built-in sensor). Perform an annual dose check on crosslinkers and irradiation systems, and inspect observation equipment every quarter for scratched glasses or filters.

Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447

SiteMap

Official WeChat QR code

WeChat QR
Official WeChat QR code Follow

Official WeChat QR code

Contact

131-2093-6518

Top