Xinysun Instrument (Shanghai) Co., Ltd.

Solutions

Breadcrumb: Home > Solutions > Speed Measurement

LUYOR ROLS-5PW Laser Tachometer Sensor: Long-Distance High-Precision Rotation Speed Acquisition for Rotating Equipment

Updated:2026-11-02Views:

The ROLS-5PW is a fixed-mount laser speed sensor: no display and no battery, mounted permanently beside the machine it watches, sending speed to a panel meter, PLC or data logger as a 5V TTL pulse. Range 1-300 000 rpm, working distance up to 7 m, and an internal filter that holds steady under workshop lighting. This article sets out how it differs from a handheld tachometer, how to pick a model in the same series, and the installation details that matter on site: reflector tape, distance, angle, bracket, cable routing and shielding.

The LUYOR ROLS-5PW is a fixed-mount laser speed sensor: it has no display of its own and no battery, and it sits permanently beside the machine it watches, sending speed continuously to a panel-mounted speed indicator, a PLC or a data acquisition instrument as a 5V TTL pulse. The measuring range is 1-300 000 rpm, the working distance reaches 7 m, and a high-frequency filter circuit built into the lens keeps the output stable under workshop lighting and outdoor stray light. It suits situations where "speed has to go into the system, be recorded continuously, and raise an alarm".

In one sentence: how it differs from a handheld tachometer

The ROLS-5PW takes a different route - fixed installation, continuously online, turning speed into an electrical signal that can enter a PLC, a DCS or a chart recorder.

The test is simple: if the need is "someone walks over and takes a reading", choose a handheld meter; if the need is "an abnormal speed has to be reported automatically", "speed has to go into the control system" or "six months of speed trend has to be kept", a fixed sensor such as the ROLS-5PW is the tool. The two are not substitutes: on many sites the handheld meter handles route inspection and the fixed unit handles online monitoring, and both run in parallel.

Key specifications at a glance

ItemPublished valueWhat it means on site
Measuring range1-300 000 rpmThe 1 rpm floor covers barring and very low speed; the top end is for turbochargers and high-speed spindles
Working distanceUp to 7 m (7.6 m or less advised)Closer mounting returns more light; do not treat 7 m as a design value
Output signal5V TTL pulse (PNP)Feeds a data logger, a PLC pulse channel or a stroboscope external trigger directly
Power supply5 V dc, about 35 mALow consumption, a module supply is enough; for 24 V systems choose the ROLS24 version
Laser650 nm, output power < 2 mW, Class 2Do not look into the beam or its mirror reflection; keep the beam path in mind when mounting
Ingress protectionIP60Fully dust-tight, not water-tight; soiled surfaces are wiped, never washed
Cable2.4 m three-core shielded as standard; 7.6 / 15 / 30 / 60 m optionalIf the mounting point is far from the cabinet, order the long-cable version; do not splice your own
Signal indicatorBlue LED on the rearFlashes once per pulse received; at high speed it looks steady and can be used as a quick alignment check
Operating temperature-10 to 50 ℃Measure the temperature around the point; near a heat source add shielding or airflow
Weight and mountingAbout 38 g, with mounting post and L bracketSmall enough to reach narrow positions inside machine guards

How to choose: picking a model in the same series

The ROLS-5PW is a series rather than a single model, and site conditions change the choice. The table below matches the options to actual duties:

Site condition / needRecommended approach
The cabinet supplies 5 V dc and the cable run is normalChoose the ROLS-5PW (2.4 m cable as standard)
The site runs a 24 V supply and no step-down module is wantedChoose the ROLS24-5PW and take power from 24 V directly
The sensor is mounted some way from the cabinetChoose the 7.6 m cable version (ROLS-5PW-25 / ROLS24-5PW-25); 15 / 30 / 60 m can be ordered
No 5 V supply is available on siteAdd a 5 V DIN rail power module, for example a Mean Well MDR-10-5
The logger or PLC accepts 0-10 V or 4-20 mA aloneAdd a signal converter to turn the TTL pulse into an analog value
Fixed mounting is needed, but occasional readings elsewhere tooChoose the SPLS-5PW with built-in battery and display, in effect a split portable laser tachometer
An occasional reading, no need to enter the systemA portable meter is more economical; see the portable laser tachometer section
Machine at ambient temperature, budget is the priorityConsider the LED photoelectric ROS-W / ROS-P
The measuring point stays above 70 ℃Switch to the heat-resistant ROS-HT-W-25 (125 ℃ continuous)
Outdoors, strong light, dust, or a specified ingress ratingConsider the IP67 stainless housing MiniVLS 211

How to install: three details that decide success

1. Reflector tape: 12 × 12 mm, one pass per revolution

The measuring premise is "one pulse per revolution", and the pulse comes from a piece of reflector tape. The method is to place a 12 × 12 mm patch of reflector tape on a clean, flat, dark surface of the shaft or rotating part, and confirm that it passes the laser spot once per revolution. Three common mistakes: placing it on a curved or uneven surface so the return is unstable; placing two or more patches on the same revolution so the reading doubles; placing it on bright metal that already reflects specularly, so ambient reflection mixes in and creates false pulses.

Where the measuring point runs hot, do not use the standard tape supplied; use a high-temperature target. The edges of reflector tape gradually fail as oil and dust build up, so tape is a consumable, and "check reflector tape condition" is worth adding as a fixed item on the inspection checklist.

2. Distance and angle

7 m is the effective measuring limit, not a recommended value; return intensity falls with the square of distance, so closer is more reliable. As for angle, keep the laser as square to the target as possible - the greater the deviation, the shorter the effective distance. Two traps to avoid: pointing the lens straight at a window or a light source, since the built-in high-frequency filter suppresses ambient light but long direct exposure still shortens life; and letting specular reflection from the target strike straight back into the lens, which can cause false triggering.

3. Bracket, cable and service access

The ROLS-5PW comes with a mounting post and an L bracket; in a vibrating environment these must be locked down and secured against loosening, otherwise the spot slowly drifts while the machine runs. The cable is a fixed-length three-core shielded type - do not cut and extend it, because a joint breaks the shield's continuity and introduces spike pulses near inverters and motors. Route the cable away from power cables and inverter output lines, in metal conduit or a separate trunking where necessary. Leave room at the mounting position to remove the unit and wipe the lens, and note that an IP60 housing does not suit positions with persistent condensation or water spray.

How to wire it: three conductors plus a shield

The ROLS-5PW is supplied with a three-core shielded cable. Conductor colors are defined below; check the markings on the actual unit before wiring:

Conductor colorFunctionWiring note
BrownSupply positive (+5 V)Connect to the 5 V positive; about 35 mA flows between it and the blue conductor
BlueSupply negative / common (GND / COM)Connect to the 5 V negative and share ground with the acquisition end
BlackSignal output (TTL pulse)Connect to a logger speed input channel, a PLC pulse input or the external trigger input of a stroboscope
ShieldEnclosure groundConnect to the sensor housing or cabinet chassis ground; do not tie it to signal ground

Data acquisition instruments are where this sensor is most at home. Taking the Japanese Graphtec GL240 as an example, one main unit can connect four input channels at once, and with the dedicated cable the speed curve can be recorded in the same data file as vibration, temperature and pressure channels. When connecting to a PLC or DCS, confirm that the pulse input channel accepts 5V TTL levels and set a suitable counting period and filter time. To drive a stroboscope for synchronous observation, feed the black signal conductor into the stroboscope's external trigger input.

How to troubleshoot: four common field symptoms

SymptomCommon causeAction
No signal at allNo supply, or polarity reversed; reflector tape missing or fallen off; lens blocked by oil or dustMeasure 5 V between brown and blue; fit a 12 × 12 mm patch of reflector tape; wipe the lens with a soft cloth (no organic solvent)
A signal, but the reading is half or a third of the actual valueMore than one patch on the revolution; or another reflective object in the beamKeep a single patch and avoid highly reflective surfaces and polished part edges
Jumping readings, many spikesShield not connected or grounded at the wrong end; cable run parallel to power lines; spliced extension breaking the shieldGround the shield to the housing; route the cable in a separate trunking; use the factory long-cable model instead of a splice
Unstable in daylight or outdoorsSunlight or strong lighting straight into the lens, beyond the filter circuit's rejection marginChange the mounting direction to avoid direct light; add a simple shade; shorten the measuring distance to improve signal-to-noise if needed

Typical applications

  • Wind and hydroelectric power: continuous online monitoring of generator rotor and turbine main shaft speed, with the signal fed into the unit monitoring system;

  • Large diesel and internal combustion engines: crankshaft and flywheel speed acquisition, recorded with the test bed system as a speed curve;

  • Dynamic balancing test rigs: a one-pulse-per-revolution reference speed for the balancing machine, the basis for calculating unbalance phase;

  • Rotor and propeller testing: speed measurement of helicopter rotors and propellers from a distance, with personnel working outside the safety zone;

  • Turbochargers and high-speed spindles: the 300 000 rpm top end covers very high speed points;

Frequently asked questions

Does the ROLS-5PW need reflector tape?

It does. This type of sensor relies on reflector tape to return the beam to the receiver, and tape returns far more light than an ordinary surface; a patch is what makes the once-per-revolution pulse reliably distinguishable. Polished metal and white painted surfaces can also return light at certain angles, but their repeatability and contamination tolerance are far poorer than tape, and the reading comes and goes.

Where can the reflector tape go, and is there a size requirement?

Place it on a clean, flat surface of the shaft or rotating part; 12 × 12 mm is the usual size, ensuring one pass of the laser spot per revolution. On a very small shaft or a curved surface the patch bends with the curve and the return area shrinks, in which case mounting the sensor closer compensates.

The sensor is not water-tight; is that a problem in a workshop?

IP60 means "fully dust-tight, not water-tight". Dust and oil mist in a workshop generally do no harm, but water spray, direct jets of mist and persistent condensation are not suitable. If the mounting point has to face a spray or washdown stage, add a protective cover or move the mounting position.

Can it connect straight to a PLC or data logger?

Yes, provided the acquisition end can supply 5 V and the pulse input channel accepts 5V TTL levels. If the site is a 24 V system, choose the ROLS24-5PW version directly; if the acquisition end accepts 0-10 V or 4-20 mA alone, add a signal converter.

How long does the laser last, and can it be replaced in the field?

The LED laser has a nominal life of 5000-20000 hours and is a consumable; brightness falls with accumulated use. The internal components need professional equipment to service, so users should not dismantle the unit; contact us through the service channel when maintenance is needed. This is also why some clearance for removal is advised at installation.

Conclusion

The value of the ROLS-5PW is not the single point of "measuring accurately" but the conversion of speed into a standard signal that can enter a system: it runs from a 5 V supply, it outputs a universal TTL pulse, and one logger can take several channels at once. Confirm three things when selecting - whether the site supply is 5 V or 24 V, how far the mounting point is from the cabinet, and whether the acquisition end needs TTL or an analog value - and once these are settled the model and accessories become clear. For help with selection, wiring diagrams or installation advice, contact us.

Related sections and models

This article belongs to the speed and stroboscopic measurement section.

Other sections in the same product line include speed sensors (wired to a PLC or acquisition card for continuous monitoring, output as an electrical signal), laser tachometers (aim at the reflector tape and read RPM directly, one-handed) and industrial test instruments (the entry point for UV inspection, speed measurement, stroboscopic observation and surface inspection).

Ranges, accuracy and accessory lists for each model are given on the product pages.

  • Official WeChat QR code

    Email: info@xinysun.com

  • Tel: 131-2093-6518

  • Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai

Official WeChat QR code Follow

Official WeChat QR code

Contact

131-2093-6518

Top