Xinysun Instrument (Shanghai) Co., Ltd.

About Us

ABOUT

Breadcrumb: Home > About Us > Company News

An Aerospace Enterprise Purchases Our ROLS-5PW for Long-Term UAV Propeller Speed Monitoring

Updated:2026-11-16Views:

An aerospace vehicle developer purchased our ROLS-5PW laser tacho sensor and LUYOR-910XA-DC-RS485 tacho display for speed measurement and long-duration recording during UAV propeller ground bench tests. The scheme replaces contact measurement and manual meter reading with non-contact laser pickup and RS485 upload, and the equipment has been installed, commissioned and handed over. Thrust, power and efficiency are comparable when each test point is tied to a specific speed, so the sensor reads a white mark on the hub, one TTL pulse per revolution, and the display streams the value over Modbus-RTU to a host for timestamped storage. This article records the delivery in four parts: requirement, configuration, on-site implementation and outcome.

The figures quoted here are the nominal values of these models and the configuration supplied on this site; they are not a general commitment for every operating condition. Actual range, alarm values and communication settings have to be set item by item against the on-site speed range and the host protocol.

An aerospace vehicle developer recently ordered a ROLS-5PW laser tacho sensor and a LUYOR-910 series tacho display (model 910XA-DC-RS485) from us, for speed measurement and long-duration recording in UAV propeller ground tests. The equipment has been installed, commissioned and handed over.

Requirement: rotational speed is the baseline for the whole test data set

Thrust, power and efficiency of a UAV propeller on a bench are comparable when each point is tied to a specific speed. If the speed is measured badly, the curves downstream cannot be put together at all.

The customer had run into two problems. Contact measurement needs a gear or a sensing element fitted to the rotating part, and there is no suitable place on the hub or the motor end. And because a test often runs continuously for ten minutes to several tens of minutes, having someone stand at the meter and copy numbers is both incomplete and likely to miss speed fluctuations during loading.

In other words, the customer wanted more than a meter that shows a number: they wanted a data channel that carries speed into a file continuously and automatically.

Solution: non-contact laser pickup, RS485 into the PC

For this duty we proposed a ROLS-5PW laser tacho sensor with a LUYOR-910XA-DC-RS485 tacho display, with a clear division of work between the two.

StageDeviceWhat it does
AcquisitionROLS-5PW laser tacho sensorAims at the mark on the rotating part and outputs one TTL level pulse per revolution, with no contact to the rotating part at any point
Display and uploadLUYOR-910XA-DC-RS485 tacho displayReceives the pulses and shows speed locally, and sends the data out over RS485 (Modbus-RTU standard protocol), so it can communicate directly with a PC, PLC or other host
RecordingHost softwarePolls the speed register at a set interval and writes speed and time together into the record file

With that division, there is a meter on the bench that can be read directly, while the control room reads the speed register over Modbus-RTU and saves it at the sampling interval, so long continuous monitoring can run.

Key specifications of the two devices

The main figures the customer checked during selection are below, all taken from the nominal values of these models.

ItemROLS-5PW laser tacho sensor
Speed range1-300000 rpm
Working distanceUp to 7 m; for close measurement keep above 10 cm
Supply5 V DC, operating current below 30 mA
ProtectionShort-circuit, reverse-polarity and 15 V overvoltage protection
Ingress protectionIP60
Output signalTTL level pulse, high level about 3-5 V, low level about 0.2 V, one pulse per revolution
ItemLUYOR-910XA-DC-RS485 tacho display
Range5-999999 RPM
Accuracy±0.001%
Display6-digit LED
AlarmUpper and lower alarm values configurable
CommunicationRS485, Modbus-RTU standard protocol
Parameter retentionSettings stored in non-volatile memory; no reset needed after a power cycle

Implementation: four steps on site

Marking and alignment. Draw a mark with a white marker pen on the rotating part of the motor or on the hub, and aim the sensor at it. A marker pen is easier than reflective tape on a curved hub; the blue indicator on the back of the sensor lights and goes out as the mark passes, which shows whether the signal is valid without waiting until the rotor spins up to troubleshoot. Why reflective stickers do not survive above ten thousand rpm, and how to draw the mark, is covered in the note on marking methods for bench speed measurement.

Distance and angle. Keep the sensor at least 10 cm from the marked surface and let the spot fall on the mark. If the reading jumps by a multiple, it is usually over-counting from multiple reflections off the blades; adjusting the angle clears it.

Range and communication. Set the display range and the upper and lower alarm values against the actual speed range on site; on the RS485 side set the station number, baud rate and parity bit to match the host, then establish communication. The parameters are held in non-volatile memory, so nothing has to be re-entered after a power cycle.

Long-duration recording. The PC software polls the speed data at a set interval and saves speed and time together. When a run ends, the whole loading and speed-change history can be traced back.

Results

After commissioning, the customer can read real-time speed in the control room and record it at the same time, with no one standing at the bench copying numbers. Speed fluctuations during blade loading and speed changes are recorded in full, which provides the basis for later thrust-speed curves. Because pickup is non-contact, there is no mechanical contact between sensor and rotating parts, so the aerodynamic state of the blades is not affected.

Looking back at this delivery, the difficulty was not the range or accuracy of a single instrument but joining acquisition, display, upload and storage into one chain without a break. A bench test can run for tens of minutes, and if any link is filled in by hand, a stretch of the time axis goes missing.

Selection and commissioning support

We can supply ROLS-5PW and SPLS-5PW laser tacho sensors, LUYOR-908/910 series tacho displays, and matching cables and reflective marking material, with selection and on-site commissioning support. Product pages and selection data are in the tacho sensor section and the tachometer section; common selection questions are covered in how to choose a laser tacho sensor. For UAV rotors, ducted fans, motor propeller benches and similar speed measurement work, please contact us.

Common questions

Why not use contact speed measurement here?

The customer's hub and motor end had no place to fit a gear or sensing element, and fitting one would change the dynamic balance and aerodynamic state of the rotating part. The non-contact laser method needs a mark on the surface and does not modify the rotating part itself.

What does RS485 solve that reading the dial does not?

The dial gives a local reading; RS485 gets the data out. Polling the speed register over Modbus-RTU and saving it with a timestamp is what lets the loading and speed changes of a long test be traced in full, rather than leaving a few hand-copied points.

What usually causes a reading to jump by a multiple?

It is usually over-counting from multiple reflections off the blades or a reflective surface, which shows up as the reading stepping up by a multiple. Adjusting the angle of incidence so the spot avoids the reflecting blade face clears it; the rear indicator can also confirm one light-and-dark cycle per revolution.

Does a white marker mark hold at high speed?

Reflective tape on a curved hub tends to lift and come off under centrifugal force, while a marker coating adheres more reliably and is easy to touch up. The actual criterion depends on the speed range; see the note on marking methods for bench speed measurement.

Do the communication settings need re-entering after a power cut?

No. The station number, baud rate, parity bit, range and alarm values are all held in non-volatile memory, and the unit resumes with the same parameters after a power cycle.

Which other benches suit this configuration?

UAV rotors, ducted fans, motor propeller benches and similar setups that need non-contact speed measurement with long-duration recording. What changes is mainly the marking position, the sensor distance and angle, and the sampling interval set on the host.

This delivery is an application record in the company news section; company background and the product lines we represent are under about us. To check parameters against your bench conditions or to arrange on-site commissioning, contact us directly.

Xinyisheng Instruments (Shanghai) Co., Ltd.

Address: Room 325, Floor 3, Building 26, No. 1525 Minqiang Road, Songjiang District, Shanghai

Tel: 131-2093-6518 Email: info@xinysun.com Website: www.xinysun.com

  • Official WeChat QR code

    Email: info@xinysun.com

  • Tel: 131-2093-6518

  • Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai

Official WeChat QR code Follow

Official WeChat QR code

Contact

131-2093-6518

Top