Breadcrumb: Home > Solutions > Speed Measurement
Updated:2026-11-17
Views: A laser speed sensor is a probe fixed beside the machine that outputs a continuous pulse train, and the key difference from a handheld tachometer is that it has no display: it measures an ongoing signal rather than a single reading. This article covers four selection decisions - laser or photoelectric light source, measuring range, mounting distance and offset angle, and output form - using the LUYOR ROLS-5PW as the reference. That model covers 1-300,000 rpm at a 7 m mounting distance with 5V TTL/PNP output, and pairs with the LUYOR-910 panel meter or a PLC. Wiring, reflective tape, and installation points are included, with answers to seven common questions.
A laser speed sensor is a measuring probe mounted permanently beside the machine that outputs a continuous speed pulse. Its key difference from a handheld laser tachometer is that it carries no display of its own and measures an ongoing pulse signal rather than a single reading. Connected to a LUYOR-910 panel-mount tachometer it gives local display and alarm; connected to a PLC or a data logger it supports long-term recording, trend analysis, and overspeed interlock. Selection has to answer four questions: light source (laser or photoelectric), range, mounting distance and offset angle, and output form. This article works through those four in order, with common questions at the end.
A note on terms. By light source, laser speed sensors divide into laser and photoelectric (LED) types; by cable exit, into plug and flying-lead versions; by supply, into externally powered and self-powered. Xinysun Instruments (Shanghai) Co., Ltd. supplies and supports LUYOR products in China, and its current range covers all of these forms. Section page: speed sensors.
The light source decides how far away the target can be, how steeply the sensor can be mounted, and how well it rejects ambient light:
| Light source | Example model | Working distance | Offset angle | Character and application |
|---|---|---|---|---|
| Visible red LED | ROS-P/ROS-W | within 0.9 m | 45° | Green targeting indicator at the cable end, lower cost; short-range speed measurement in ordinary shops |
| Incandescent white | ROS-HT-W-25 | 0.76 m | 30° | Withstands -25 to 125 ℃, spot landing point visible to the eye; engine bays, dynamometers, and other hot locations |
In one sentence: within 1 meter and with budget as the priority, choose photoelectric (LED); beyond 1 meter, with an angled mount or strong ambient light, choose laser. For a more detailed comparison of light sources, see the LUYOR speed sensor selection guide.
| Step | What to look at | How to decide |
|---|---|---|
| 1. Range | Upper speed limit of the target | For ordinary motors and fans a 250,000 rpm range is enough; for motor spindles, dental drills, turbos, and drone rotors choose the 1-300,000 rpm (1-5000 Hz) range of the ROLS-5PW |
| 2. Distance and offset | Where the sensor can be mounted and whether the beam path is blocked | Design to about 70% of the upper limit as margin; where pipes or guards block the path, a laser version with a 60° offset angle lets the sensor be tucked where it is out of the way |
| 3. Output form | Whether the back end is a panel meter, a PLC, or a data logger | For direct 5V TTL/PNP acquisition choose the ROLS-5PW; for sourcing or sinking PLC inputs choose NPN or PNP by model; for terminal-block wiring choose a flying-lead version. See the full wiring and output guide |
| 4. Supply and accessories | Whether 5V/24V is available on site | Use the 5V version near a control cabinet; where a 24V bus is present choose the ROLS24 series; at inspection points without power choose the self-powered SPLS-5PW |
| Model | Light source | Range | Distance / offset | Output | Supply | Features |
|---|---|---|---|---|---|---|
| ROLS-5PW | 650 nm modulated laser (Class 2) | 1-300,000 rpm | 7 m | 5V TTL / PNP pulse | 5 Vdc | Built-in high-frequency filtering for ambient light; 38 g, IP60; signal cable extendable to 100 m; online monitoring at very high speed and long distance |
| 650 nm laser | 1-250,000 rpm | 7.6 m / 60° | Open collector | 5-24V | 3.5 mm plug, plugs directly into handheld tachometers, stroboscopes, and the SPSR-IM power module | |
| 650 nm laser | 1-250,000 rpm | 7.6 m / 60° | Open collector | 5-24V | Three tinned leads, straight into the terminal block of a panel meter, frequency converter, PLC, or data logger | |
| SPLS-5PW | Uses the ROLS-5PW sensor | 1-300,000 rpm | 7 m | BNC, 0-5V TTL | Internal lithium battery, about 60 hours / 115-230Vac | Module carries its own 99999 RPM display; effectively a split portable laser tachometer that keeps the signal output |
| ROS-P/ROS-W (photoelectric comparison) | Visible red LED | 1-250,000 rpm | 0.9 m / 45° | Negative pulse | 3-15 Vdc | Targeting indicator at the cable end; short range, controlled ambient light, budget-priority situations |
Within the same family and form factor there are further supply and cable variants: the ROLS-5PW family covers four combinations of 5V/24V supply and 2.4m/7.6m cable (ROLS-5PW, ROLS-5PW-25, ROLS24-5PW, ROLS24-5PW-25);
| Site situation | Recommended model | Reason |
|---|---|---|
| High-speed motor spindles, dental drills, turbos, drone rotors | ROLS-5PW | 300,000 rpm range and 5000 Hz bandwidth, TTL/PNP straight into the logger |
| Measurement point high up or in a hazardous area, out of reach | ROLS-5PW or ROLS-P/W | 7-7.6 m mounting distance keeps the sensor out of the hazardous area, with the lead run back to the cabinet |
| Handheld tachometer plug-in, measure on the spot | 3.5 mm plug, ready to use | |
| Terminal block wiring, fixed installation inside a PLC cabinet | Tinned leads crimped straight into the terminals | |
| Inspection points without power, temporary installations | SPLS-5PW | Self-powered with display, BNC straight to the instrument |
| Engine bays, cooling systems, and other hot conditions | ROS-HT-W-25 | Withstands -25 to 125 ℃, incandescent spot visible to the eye |
| Ordinary shop, short range, budget priority | ROS-P/ROS-W | Within 0.9 m, with targeting light, lower cost |
Choosing the right probe is half the job; poor installation still gives unstable readings. A few field notes:
The core difference is the light source and the distance, offset angle, and noise immunity that follow from it. Laser versions (ROLS series) use a 650 nm class laser with a fine beam and small spot, hitting the tape reliably at 7 m and 60° offset, which suits long distance, large offset, and strong ambient light. Photoelectric versions (ROS series) use a visible red LED over 0.9 m at 45°, with a targeting indicator at the cable end and lower cost, which suits short-range measurement in ordinary shops. Choose by mounting distance: photoelectric within 1 meter, laser beyond it.
The 1 rpm lower limit corresponds to about 0.017 Hz, but in practice the low end is constrained by the size of the reflective tape and the pulse counting time, so at very low speeds the reading refreshes more slowly. In engineering terms readings are stable above 10 rpm; below that, enlarge the tape area or use several marks per revolution (noting that the receiving end must be set up for one pulse per revolution).
Yes. The ROLS-5PW outputs a 5V TTL-level PNP (sourcing) pulse: connect the brown lead to +5V, the blue to GND, and the black to the PLC digital input. Two things must be confirmed: the PLC input's turn-on threshold is below the output low level, and the input's voltage rating is above the 5V high level. Where the input is a sinking type, use a model with NPN output and add a pull-up resistor. Where 4-20mA, RS485, or relay alarm output is needed, add a LUYOR-912 speed transmitter / speed monitor to convert the pulse into a standard signal for the DCS or SCADA system.
The standard cable is 2.4 m of three-core tinned shielded cable, with 7.6 m available; with your own extension the total can reach the 100 m class. Any extension must use shielded cable with the shield grounded at one end, routed separately from power cables and drive feeders, otherwise edges soften and noise becomes likely.
A Class 2 laser emits less than 2 mW, and under normal conditions the blink reflex is enough to protect the eye, but direct viewing of the beam and viewing the path through optical instruments should still be avoided. In installation, simply point the beam at the target; no extra protective clothing is needed. In routine checks, confirm the bracket is not loose and the lens is not obscured by oil or dirt.
Not reliably. A reflective probe depends on a reflective mark on the target surface to produce one pulse per revolution; without tape the reading drifts or pulses are lost. Clean the shaft or pulley and apply T5 tape. Where the surface itself has a keyway, a boss, or high reflectivity, the LUYOR MT-190P magnetic sensor is an alternative - ask for a quotation to confirm.
A panel-mount tachometer is a local display and alarm instrument installed into a control cabinet panel, working as a separate unit from the sensor: the sensor at the measurement point outputs one pulse per revolution, and the panel meter handles display, overspeed alarm, and analog output. The LUYOR-910 panel-mount tachometer installs through a panel cutout with a range of 5-999 990 rpm and 0.001% of reading accuracy, dual relay alarms, 0-5V/4-20mA output and optional RS485; connect the brown, blue, and black leads from the ROLS-5PW and it displays immediately.
This article belongs to the common questions section.
Other sections on the same product line include speed sensors (continuous monitoring into a PLC or DAQ card, delivering an electrical signal), laser tachometers (aim at reflective tape and read RPM directly, one-handed), and industrial test instruments (the entry point for UV inspection, speed measurement, stroboscopic viewing, and surface inspection).
Ranges, accuracy, and accessory lists for each model are given on the product pages.
Email: info@xinysun.com
Tel: 131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447