Views: In January 2024, the group of Fan Yubo at Beihang University, with researcher Xu Gaolian at Shanghai Jiao Tong University, published a ctDNA detection platform in ACS Nano: a self-powered chip based on free-flow ion concentration polarization that enriches circulating tumour DNA in 30 seconds, an on-chip array of 100 microwells for LAMP, and readout from two parameters - the number of positive wells and the fluorescence intensity of each well - with a limit of detection of 100 copies/mL. This article takes apart the readout step of that system and explains how the LUYOR-3260RB fluorescence protein excitation source, the observation tool used in the paper, is applied to fluorescent microwell interpretation.
ctDNA (circulating tumour DNA) is DNA released into the bloodstream by tumour cells, carrying key information about tumour onset and metastasis, and it is the core marker of liquid biopsy. It has three inherent difficulties: very low abundance, a share of just 0.5%-10% of total circulating cell-free DNA, a half-life of under 2 hours, and a complex sample matrix (serum, urine and stool all carry large amounts of PCR inhibitors). Conventional detection relies on magnetic bead or silica membrane extraction, which is laborious and slow, and low-abundance samples easily produce false negatives because too little input material is available.
The idea in this work is to press "enrichment - amplification - readout" onto a single self-powered chip: the enrichment zone pulls nucleic acid out of a complex matrix within 30 seconds by FF-ICP, a Y-shaped channel carries it into the detection zone, LAMP runs at 65℃ and the fluorescence is read directly - sample in, result out, without leaving the chip.
The principle of ion concentration polarization (ICP) is not complicated: with a vertical electric field applied across a cation-selective Nafion membrane, negatively charged nucleic acid molecules experience a downward electro-osmotic force (EO) and a rising electrophoretic force (EP), and are "trapped" where the two balance, forming an enrichment band. Add a horizontal driving force and the enriched nucleic acid is pushed continuously into a collection channel - this is "free-flow ICP (FF-ICP)", in which separation becomes a continuous flow process instead of a single batch step.
The part that drives the horizontal flow is neat: a "vacuum battery" built into the chip uses pre-degassed PDMS to exchange gas between a vacuum channel and a liquid channel, generating about 60 kPa of negative pressure to push the liquid, with no external pump and no power supply at any point.
| Item | Magnetic bead / silica membrane extraction + PCR | FF-ICP chip + LAMP |
|---|---|---|
| Enrichment time | Tens of minutes, several transfer steps | Enrichment peak reached within 30 seconds |
| Operation | Centrifugation, transfer and elution, several manual steps | Self-driven continuous run after sample loading |
| Enrichment performance | Commercial kit as the benchmark | About 5 times more DNA enriched at the same concentration, lower qPCR Ct |
| Limit of detection | Limited by low-abundance input | 100 copies/mL, a 100-fold sensitivity gain |
| Interference resistance | Residual inhibitors affect amplification | Purification and amplification stable with PCR inhibitors present |
Optimised conditions: enrichment efficiency peaks at a flow rate of 15 μL/s and a voltage of 100 V. In EGFR exon 19 deletion testing on serum from 38 patients with non-small cell lung cancer, low-abundance samples were no longer missed for lack of concentration, and ctDNA levels in early-stage patients were lower than in advanced patients, so the chip reading reflects disease progression. Validation on urine and stool samples was completed as well.
The detection zone holds 100 microwells pre-loaded with LAMP reagent, running isothermal amplification at 65℃. Quantification uses two parameters: the total number of positive microwells and the fluorescence intensity of each well, converted to concentration with a Poisson distribution model - between 10 and 1000 copies/μL the measured probability agrees closely with the theoretical curve (R² above 0.99).
It is worth noting that "looking at the fluorescence" is the step with the lowest barrier to building in an ordinary laboratory: LAMP products are developed with SYBR Green type dyes, excitation and emission both fall in the visible range, and the result can be read either on a fluorescence plate reader or directly under a simpler blue light source.
Once SYBR Green binds double-stranded DNA, the excitation peak is about 497 nm and emission about 520 nm, so 450 nm deep blue falls in the effective part of its excitation spectrum. The paper used the LUYOR-3260RB to read the microwells: handheld 450 nm deep blue excitation with the matching 500 nm long-pass viewing glasses, which block the reflected blue light and transmit green - positive wells glow green, negative wells stay dark, and the result is read by eye. Nine 3 W LEDs form a spot of about 150 mm at 30 cm, covering the 100-well array in one exposure, and a phone photograph can be kept as a record for comparing brightness between wells. The 12 V lithium battery runs for 2-4 hours, so the lamp works at the bench and beside the clean bench.
| Scene | How the LUYOR-3260RB is used | Note |
|---|---|---|
| Fluorescence reading of a microwell array | About 150 mm spot at 30 cm, covering the chip array | Covers all 100 microwells at once, even illumination between wells, suited to counting positive wells |
| Handheld scanning and photographic records | 500 nm long-pass glasses plus a phone camera | Scan the wells row by row, shoot at a fixed angle and distance, compare brightness between wells |
| GFP / eGFP reporter screening | The same source for transgenic material | Shared by callus, colony, seed and seedling GFP screening, with no change of equipment |
| Fluorescein and calcein observation | 450 nm excitation of live material or labelled samples | No substrate development needed, direct excitation, extends to cell viability and labelling work |
The limits should be stated as well: a handheld excitation source provides qualitative reading and semi-quantitative checking, and where strict quantification (copy number, Ct value) is needed, qPCR or a fluorescence plate reader remains the reference. The two are complementary - the excitation source handles quick screening, verification and teaching demonstrations, while the quantitative instrument produces the report. For band selection, dye matching and protection details on blue light and UV transilluminators, see How to choose between a blue light and a UV transilluminator: dye matching and protection for 470 nm gel cutting .
LUYOR-3260RB fluorescence protein excitation light source - 450 nm deep blue excitation and 500 nm long-pass glasses, covering LAMP microwell fluorescence reading and GFP screening in one unit; How to choose between a blue light and a UV transilluminator - the general guide to transilluminator selection; GFP flashlight section for more fluorescence observation options, or contact us for LUYOR-3260RB selection advice and a demonstration.
This article belongs to the research laboratory techniques section.
Other sections on the same product line include GFP flashlights (models sorted by GFP/RFP/DsRed band, handheld and benchtop) and life science instruments (the entry point for fluorescence imaging, UV crosslinking, UV transmission and cell irradiation).
Models mentioned: LUYOR-3260RB, LUYOR-3415RG, LUYOR-3421. Ranges, accuracy and accessory lists for each model are given on the product pages.
Email: info@xinysun.com
Tel: 131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447