Xinysun Instrument (Shanghai) Co., Ltd.

Solutions

Breadcrumb: Home > Solutions > Fluorescent Inspection

What Is Oil-Free Degreasing (OC)? Treatment Methods and Standard Specifications

Updated:2026-11-17Views:

What does the OC marking for oil-free degreasing on a drawing actually require, how is the degreasing carried out, and to which standards is it accepted? Those three questions form one continuous chain of work: understand the requirement, decide the cleaning method, then know how to prove the part is clean. This article unpacks the quantitative criteria for OC, the surfaces that have to be treated, four degreasing methods and three families of chemicals, and explains the UV check at the acceptance step, including which fluorescence is oil and which is not.

People working on oxygen piping, air separation plants and medical gas projects are regularly stopped by three questions: what the "oil-free degreasing OC" note on the drawing actually means, which treatment methods exist, and to which standards the work is accepted. Taken together these three form a complete chain of work: understand what is required, decide how to clean, then know how to prove that the cleaning worked. This article follows that order and explains the role of the LUYOR-2130L degreasing inspection black light in the closing link of the chain - acceptance.

1. What oil-free degreasing and OC mean

1.1 Taking the three words apart

"Oil-free" is the requirement, "degreasing" is the process, and "OC" is the delivery state. The three describe one thing at three levels, and they are often used interchangeably when technical requirements are written, which leads to different readings on site.

TermMeaningWhere it lands
Oil-freeOil-type substances are not permitted to contact the component or system; a management and design constraintTechnical conditions, drawing notes, packaging and storage requirements, assembly and pressure test rules
DegreasingThe construction step of removing surface grease with solvent, alkaline solution or emulsifierConstruction plan, process handover, cleaning process card
OC (Oxygen Clean)The acceptance conclusion for an oxygen-clean state, meaning the part has reached a cleanliness suitable for oxygen contactInspection records, pass labels, handover documentation

So the full reading of "oil-free degreasing OC" is: this is an oil-free part, it must be degreased, and it must meet the oxygen clean (OC) acceptance requirement. It is not an optional cleaning step but a mandatory requirement tied directly to safety.

1.2 Why oxygen-contact surfaces are treated so strictly

Oxygen itself does not burn, but it is a strong oxidizer. In air at atmospheric pressure, steel and copper do not burn; in a pure oxygen environment they can burn continuously. Grease left on the inner wall of a pipe is energized and heated by high-velocity flow and particle impact, and once it passes the ignition point the metal of the wall ignites; the pure oxygen then feeds the fire, which can burn through the wall and lead to deflagration of the system.

Risk scales with three variables: the higher the oxygen purity, the greater the hazard, the higher the pressure and flow velocity, the greater the hazard, and the more severe the throttling, the greater the hazard (velocity is higher at elbows, tees and valves). This explains why degreasing requirements are particularly strict for oxygen lines in cryogenic air separation plants, the inlet and outlet of oxygen compressors, oxygen branch lines in gasification units, and medical central oxygen pipelines.

1.3 Two quantitative criteria for OC

"Clean" cannot rest on impression; engineering uses measurable residual limits. Two criteria are often cited:

  • ASTM G93-96: oxygen system cleanliness is commonly judged by a surface oil content below 1 g/m². One gram per square meter is roughly less than half a drop of oil spread thinly over the area of an A4 sheet.

  • GB/T 12244-2021 "Valves for oxygen service - Technical specification": residual grease on the valve bore and sealing faces is commonly required to be no more than 125 mg/m², and the valve must be dried after degreasing.

The specific limit is governed by the project design documents, tender documents and contract - values differ between industries and pressure classes.

1.4 Which surfaces have to be treated

On the principle of full coverage of wetted surfaces, every internal surface that can contact oxygen is in scope: pipe and fitting bores, flange sealing faces, welds and heat-affected zones, threaded joints, elbow and tee bores, valve bores and seat sealing faces, gaskets, blind plates, tank and vessel heads, and every connection opened before installation. Pipe exteriors, supports and structural parts that do not contact the medium are usually outside the degreasing scope.

2. What degreasing methods are available

Methods divide into two layers: how to clean and what to clean with. They are chosen separately, because the same chemical behaves very differently under different methods.

2.1 Choosing among four degreasing methods

MethodSuitable forAdvantagesLimitations
Immersion (tank) methodRemovable pipe sections, flanges, valves, gaskets, fastenersFull coverage of internal surfaces, even result, batch processingRequires a degreasing tank and floor space; unsuitable for very long sections or lines already installed
Wipe / swab methodValve bodies that cannot be immersed, scattered areas, pipe endsFlexible, allows local treatment, simple toolingLow efficiency, result depends on how carefully the work is done; fabric fibers are easily left behind
Circulation (forced circulation) methodLong lines already installed, large-diameter mainsCovers the whole system in one pass, uniform result along the run, saves laborNeeds a cleaning pump station and temporary loop, and heavy preparation
Spray methodVessel interiors, large-diameter pipe sectionsLarge coverage, can treat big cavitiesNeeds dedicated equipment, and spray shadows remain

One line on selection: if a prefabricated section can be immersed, immerse it for an even result; for a long line already installed, use circulation, which is less labor and more reliable than wiping section by section - manual wiping tends to give different results from one crew to the next.

2.2 Three families of degreaser and what to watch

TypeExamplesAdvantagesCautions
Organic solventsTrichloroethylene, acetone and similar; carbon tetrachloride is now largely restrictedStrong degreasing power, works at room temperatureToxicity, volatility and controlled-substance issues are prominent; strict ventilation and personal protection are required, and no water carry-over is allowed
Water-based alkaline3-5% sodium hydroxide solution, steam-heated to about 80℃Low cost, easy wastewater treatment, can be reusedCheck compatibility with aluminium and similar materials; rinse to neutral after degreasing
Water-based neutral / emulsifyingEmulsifying degreasers containing surfactantsMild, friendly to the substrateSuited where strong alkali cannot be used; degreasing power has to be verified against the soil level

Two requirements are easily overlooked: a degreaser can itself carry oil, so solvent with oil content above the limit must be de-oiled and inspected before use; and a degreased pipe must not be pressure-tested or purged with an oil-containing medium, or the earlier work is wasted. GB 16912-2008 requires oxygen piping to be purged with oil-free dry air or nitrogen after degreasing, and prohibits chlorine-containing degreasers.

2.3 A complete process chain

The sequence usual for oxygen piping is:

Water rinse / system pressure test → degreasing → water rinse → acid cleaning → water rinse → second degreasing → water rinse → passivation → cleanliness check → oil-free air or nitrogen purge and dry

Acid cleaning removes rust and welding slag, passivation forms a protective film on the metal surface so that rust does not return after degreasing, and the cleanliness check at the end is the acceptance step covered in section 3. Once the sequence has been completed and the check passed, the part should be passivated at once or have its openings closed with dry nitrogen - a good deal of rework comes from a part that passed the check and then got dirty again.

2.4 Where oil-free rules apply beyond oxygen piping

The requirement is not aimed at oxygen alone. Any medium system that is sensitive to oil carries similar rules: high-purity gas (nitrogen, argon, hydrogen) piping, vacuum systems, refrigeration and cryogenic systems, hydrogen energy and liquid oxygen systems, and some semiconductor and precision instrument gas lines. The test is simple - if contamination of the medium by grease would affect safety, purity or function, the part should be managed as an oil-free part.

3. Which standards and specifications apply

3.1 The main standards and what each covers

StandardWhat it coversRelation to this topic
HG 20202-2000 "Code for construction and acceptance of degreasing works"Degreasing construction and acceptanceThe dedicated degreasing standard. Gives inspection methods such as UV lamp examination and the criterion "no violet-blue fluorescence means acceptable"
GB 16912-2008 "Safety technical regulations for the production of oxygen and related gases by deep freezing"Safety of oxygen production and useRequires oxygen-contact parts to be degreased, purged with oil-free dry air or nitrogen after degreasing, and prohibits chlorine-containing degreasers
GB 50235-2010 "Code for construction of industrial metallic piping"Industrial metallic piping constructionSets cleanliness requirements for oxygen piping and the pre-installation inspection step
GB/T 12244-2021 "Valves for oxygen service - Technical specification"Oxygen valvesSets limits on residual grease in the valve bore and on sealing faces
GB 50751-2012 "Technical code for medical gas engineering"Medical gas systemsSets cleanliness and inspection requirements for medical gas piping, terminals and manifolds
ASTM G93-96Oxygen system cleanlinessOften used on projects with an international scope; the criterion is usually a surface oil content below 1 g/m²

3.2 The four inspection methods in HG 20202

This is a table that gets asked about often. The four methods differ widely in how practical they are:

MethodHow it is donePass criterionFull inspection possibleEvidence retained
UV lamp examinationIrradiate the degreased surface with a UV source at 3200-3800 Å (that is 320-380 nm)No violet-blue (often yellow-green on site) fluorescence on the surfaceYesCan be photographed for the file
White filter paper wipeWipe the degreased surface with clean, dry white filter paperNo grease trace on the paperWhere the paper reachesThe filter paper can be kept
Camphor methodBlow off with oil-free steam and place the condensate around pure camphor no larger than 1 mm in diameterThe camphor particle keeps rotatingNot suited to full inspectionRequires a written record
Analytical methodSample and analyse the grease content of the degreasing bath or of the surfaceCommon criteria: grease content of the bath ≤350 mg/L; surface residue ≤125 mg/m²Not suited to full inspectionLaboratory report issued

3.3 Why UV lamp examination carries the workload

The specification requires the inspection quantity for degreased parts to be all of them, with degreasing and inspection records retained. In other words, every flange and every weld has to be looked at. UV lamp examination is the method that satisfies five conditions at once: it can be done on site, it gives a result immediately, it covers every location, it leaves an image record, and it does not damage the part. The filter paper and camphor methods suit re-checking a suspect area, and the analytical method suits quantitative spot checks and issuing a report.

About the "3200-3800" in the standard: the original unit is the angstrom (Å), 1 Å = 0.1 nm, so the conversion gives 320-380 nm, squarely inside the UV-A band. That is why degreasing inspection lamps are always 365 nm and not 254 nm - when buying a lamp, if the word on offer is just "ultraviolet", confirm that the wavelength falls in the 320-380 nm range.

4. What the LUYOR-2130L contributes at the acceptance step

Cleaning and checking are two different things. The cleaning side depends on process and chemicals; the checking side needs a lamp that can reveal weak fluorescence and still cover a whole flange circumference and a pipe end. The LUYOR-2130L is designed around this "full inspection" requirement.

Requirement that full inspection imposesCorresponding design of the LUYOR-2130L
Wavelength must fall in 320-380 nm3 × high-power 365 nm UV-A LEDs, band 360-370 nm, pure UVA without UVB or UVC
The spot has to be large enough for fast coverageSpot about 100 mm at 150 mm, about 150 mm at 250 mm, about 200 mm at 300 mm
Intensity has to be high enough for thin oil films to fluoresceAbout 25000 μW/cm² at 150 mm; about 13000 μW/cm² at 250 mm; about 10000 μW/cm² at 300 mm
White light has to be suppressed for fluorescence to be readableHigh-efficiency filter cuts more than 90% of white light; white-light illuminance at 150 mm below 15 lux
Must switch on and off often and move easilyUV-A LED cold source lights instantly, three brightness levels on a light touch; body 220 mm long, reaches into pipe ends
Must enter tight spacesFlashlight form, head 76 mm, tail 45 mm, net weight about 600 g
Working time has to be sufficientLithium battery, about 2-5 hours of continuous operation depending on the level
Battery state has to be visibleDigital battery display at the tail of the body, so the lamp does not die halfway through

UV intensity falls quickly with distance, so intensity figures always have to be read together with distance: from 150 mm out to 380 mm the center intensity drops to roughly a quarter. The usual site practice is "far then near" - sweep quickly at 250-380 mm on the middle and low levels to find suspect areas, then switch to the high level and move in to about 150 mm to confirm detail.

5. Reading on site: what passes, and which fluorescence is not oil

The pass criterion is no violet-blue fluorescence on the inspected surface. Note "none", not "very weak" - there is no intermediate grade of "slightly acceptable" in this reading.

Interference that fluoresces but is not greaseSourceHow to tell it from grease
Cotton fibers, lint from cleanroom wipesShed during wiping, carried on clothingWipes off with an oil-free white cloth; filamentous or dotted in form
Dust and inorganic particlesAirborne dust, concurrent tradesRemoved by wiping; grease spreads into a halo
Cleaning agent and degreaser residueIncomplete rinsingRe-rinse and dry per the process, then re-check; do not rush to fail the part
Rust-preventive oil, protective waxFactory protective layer not fully removedSheet-like distribution with regular edges; this is "not degreased" rather than "poorly degreased"
Marker pen strokes, label adhesiveConstruction markingFixed position, regular shape, obvious at a glance

One action that works better on site than any theory: wipe it. Rub an oil-free white cloth gently over the suspect bright spot - what comes off is mostly foreign fiber and dust; what stays, or still shows a yellow-green halo after wiping, is grease that has seeped into microscopic surface depressions. Writing this action into the work instruction is recommended.

6. Frequently asked questions

Is OC the same thing as "degreasing passed"?

Broadly synonymous, but OC puts more weight on the delivery state of "inspected against the oxygen clean requirement, with records kept". OC is the clearer term in a technical requirement, because it implies that acceptance was performed, records exist and the part is labelled.

What if the lamp will not fit into a small-diameter pipe?

Common industry practice: wipe the bore repeatedly with a clean, oil-free non-woven or white cloth, then take the cloth into a dark area and examine it under a black light. If the cloth shows no fluorescence, that section passes; fluorescence spots mean it has to be degreased again. This is the HG 20202 white filter paper method and UV lamp method applied together.

Does bright ambient light affect the reading?

Yes, and strongly. The more visible ambient light there is, the less a weak fluorescence can be seen. Where conditions allow, screen the area with a light-blocking cloth or work in a dark room; if the shop lighting cannot be switched off, hood the inspection area and look inside. Judging "pass" directly may in fact mean nothing more than that nothing was visible.

If the lamp still switches on, is it still usable?

No. UV intensity falls as the source ages, and past a certain point the fluorescence of a thin oil film can no longer be seen, so inspections "pass" smoothly until a problem appears at charging or pressure testing. The basis for judgement should be intensity data with records and a threshold: fix the level and the measuring distance (high level at 250 mm, for example), measure the center intensity under the same conditions each time and log it in the equipment file, and set a replacement threshold (for example below 70% of the initial value, send for calibration or replace). A UV radiometer can be used for this work.

Can an ordinary UV flashlight or a banknote checker be used for acceptance?

Not advisable. The usual problems are a wavelength shifted to 395 nm, no filter so too much white light, a small spot and insufficient intensity. Those three map exactly onto "no fluorescence visible", "fluorescence drowned by white light" and "a small spot that misses areas", and the outcome is a false pass. A lamp used for acceptance has to meet four points: 320-380 nm wavelength, sufficient center intensity, low white-light illuminance and a large enough spot.

How to choose between the LUYOR-2130L and a focusing UV lamp?

The test is simple: is your main worry incomplete coverage or an unclear view. Degreasing inspection of oxygen piping covers a large area and requires every location to be seen, so what you fear is a miss - take the widely distributing 2130L; fluorescent leak detection and penetrant inspection look for very small points, so what you fear is not seeing them - take a focusing high-intensity type such as the LUYOR-3180. Many organizations working on oxygen piping keep both: one for finding, one for sweeping.

7. Conclusion

Back to the three questions at the start. Oil-free degreasing OC is the combined name for "oil-free part + degreasing treatment + oxygen clean acceptance", and the criterion is a measurable limit on residual surface grease; treatment methods mean four methods with three families of chemicals, worked through the process chain before acceptance; standards start from HG 20202 as the dedicated degreasing basis and link with GB 16912, GB 50235 and GB/T 12244, with ASTM G93 often cited on projects with an international scope.

One link in that chain is especially prone to looking done when it is not: the acceptance step at the end. Grease residue does not change the color of the metal, does not change its finish and produces no smell. Making it visible takes a 365 nm lamp with the right wavelength, enough intensity, a large spot and low white light.

If a project needs the selection for a degreasing inspection plan checked (pipe diameter, locations, working time), or needs a recording scheme for UV intensity verification, send us the working conditions and we will confirm them together. Further reading: Why pipe degreasing is accepted under UV light, 365nm black light section, UV radiometer section.

Related sections and models

This article belongs to the frequently asked questions section.

Other sections on the same product line include 365nm black lights (UV surface sources for penetrant inspection, leak detection and fluorescence checks, where irradiance matters more than wattage), surface inspection lamps (low-angle grazing light that pulls particles, scratches and fingerprints out of the background) and industrial test instruments (the entry point for UV inspection, rotational speed measurement, stroboscopic observation and surface inspection).

Models mentioned in this article: LUYOR-3103, LUYOR-BBMA, LUYOR-365L. Ranges, accuracy and accessory lists for each model are listed on the product page.

  • Official WeChat QR code

    Email: info@xinysun.com

  • Tel: 131-2093-6518

  • Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai