Breadcrumb: Home > Applications > Fluorescent Leak Testing
Updated:2026-11-02
Views: Leaks in a paper mill are often just a few drops a minute, hidden under paper dust, stock and oil film; by the time oil shows on the floor or a low-level alarm trips, the problem has been building for weeks. This article maps the machine positions where leaks are common and hard to find, explains why fluorescent leak detection pays off in this setting, why water-based and oil-based tracers must never be mixed, and sets out the full workflow from dosing and circulation through section-by-section scanning to marking and recheck.
A leak in a paper mill is rarely as straightforward as a burst pipe emptying onto the floor. High-pressure hose fittings on the hydraulic power unit, rotary seals on a dryer cylinder, distributors in the lubrication system, welds on cooling water lines - at these points the seepage rate may be just a few drops a minute, hidden under paper dust, stock and oil film, and quite invisible from floor level. By the time oil appears on the floor, oil spots show up in the sheet, or a machine trips on a low-oil alarm, the problem has usually been accumulating for weeks.
That is why fluorescent leak detection is widely used in the paper industry: it turns finding a leak from an experience-based visual round into a deterministic job that can be completed inside a shift maintenance window. Below, taking LUYOR fluorescent leak detection dye used with a UV/blue leak detection lamp as the example, we set out which equipment in a paper mill is worth surveying, how to choose a dye for three kinds of fluid, and the complete process from dosing to recheck.
From pulping to papermaking, the equipment around one paper machine falls into two lines: the stock preparation line with pulpers, beaters (refiners), conical refiners, chests and stock pumps; and the papermaking line with the headbox, wire section, press section, dryer section, calender and reel. What really needs watching for leaks are the "invisible" pipes and components that supply oil and water to that equipment.
| Equipment and location | Typical medium | Leak symptoms and risk |
|---|---|---|
| Reducers and bearing housings on pulpers and stock pumps | Gear oil, grease | Oil seal seepage enters the chest, causing oil spots in the sheet and stock contamination |
| Hydraulic loading systems on beaters and conical refiners | Hydraulic oil | Pressure will not hold and the disc gap fluctuates, directly affecting freeness stability |
| Rotary joints and steam condensate lines in the dryer section | Heat transfer oil, cooling water | The leak point is wrapped in insulation, so finding it means stripping the insulation |
| Press section hydraulic power unit and high-pressure hoses | Hydraulic oil | A high-pressure fitting weeps, oil mist spreads across the roll face and leaves regular oil spots |
| Oil-lubricated parts of vacuum and compressed air systems | Lubricating oil | Oil travels with the air into the system and contaminates forming fabrics and suction rolls |
What these locations have in common: they sit high, the space is tight, they are covered by insulation or guards, and the shutdown window is short. The traditional approach is to open everything up after a shutdown, or to work backwards from oil stains on the floor - the former costs labor hours, the latter finds just the leak that has already reached the floor.
The principle is not complicated: a fluorescent tracer fully compatible with the oil in the system is dosed in proportion and circulates with the oil to every fitting and every seal. Where there is a leak, oil carrying the tracer seeps out and emits bright fluorescence under UV or blue light. A micro-seep the eye cannot see becomes a clear bright spot under the lamp.
For a paper mill the value is not just saved labor hours. Oil entering the stock system directly produces rejected paper in batches, and oil entering the cooling water system raises discharge compliance issues; finding a seep one or two maintenance cycles earlier is often worth more than the repair itself.
The usual reason a fluorescent survey fails on the spot is not a weak lamp but a mismatch between tracer and medium. An oil-based tracer added to a water system does not dissolve; it gathers into oil slicks on the surface, traces nothing, and may clog fine filters. A water-based tracer added to hydraulic oil likewise will not disperse evenly. Confirm what the system actually circulates before choosing a dye.
| System medium | Suitable model | Fluorescence color | Reference dosage |
|---|---|---|---|
| Hydraulic oil, gear oil, heat transfer oil, compressor oil and other mineral-based fluids | LUYOR-6100 oil-soluble fluorescent tracer | Yellow-white (under UV/blue light) | About 0.5-2.5 mL/L of system oil volume |
| Cooling water, circulating water, hydrostatic test water | LUYOR-6200 water-based fluorescent tracer (green) | Bright green | Dilute 1000:1 to 500:1 in water |
| Cooling water, closed circulating water circuits (where they must be told apart from other systems) | LUYOR-6300 water-based fluorescent tracer (blue) | Blue | Dosed by water volume; 500 mL treats about 3000 L of water |
Color coding is particularly useful in a paper mill: one machine often carries hydraulic oil, lubricating oil and cooling water as three separate systems, and different tracer colors tell you at a glance which one a seep comes from. The cost of using the wrong tracer is not just a missed leak - an incompatible agent that enters a system may require a complete oil change to recover.
Begin by establishing the actual oil volume of the system to be surveyed (tank capacity plus the volume held in piping, heat exchangers and accumulators, usually estimated at 1.2-1.5 times tank capacity), then calculate the dose in proportion. Prefer a dosing point on the return line or at the tank return port, so the tracer is sheared and mixed by flow on the way back rather than poured straight into the bottom of the tank.
After dosing, run the machine under its current duty. Circulation time depends on system size and flow rate: a small hydraulic power unit usually distributes the dye evenly in ten-odd minutes, while the lubrication system of a large paper machine may need tens of minutes to an hour. This step cannot be skipped - tracer that has not mixed locally leads to the false conclusion that a region does not leak.
With shop lighting as dim as practical, scan along the pipe runs section by section with the leak detection lamp, concentrating on fittings, flanges, seal faces, rotary joints and hose crimps. A seep glows brightly under the lamp, and even a micro-seep shows as a small halo. For high-level piping, use a long pole or an elevated work platform; for insulated sections, start with insulation seams and drain holes, which are often where a seep emerges.
Mark each leak point immediately with a marker or a tag, and classify it as immediate or scheduled repair by severity. No re-dosing is needed after the repair - the tracer left in the system is still there, so run for a while and check the same position again; no fluorescence means the repair is sound. This closed loop is the most concrete advantage of fluorescent detection over traditional methods.
At the recommended ratio the tracer makes up a very small share of the oil and does not change the viscosity grade or the main lubrication properties. The preconditions are the right model for the medium and no overdosing. If the system has strict cleanliness or certification requirements for its oil, take a sample and confirm compatibility beforehand.
It is worth distinguishing them. Yellow-white for hydraulic systems, green or blue for cooling water; during a round, the color of the glow tells you which circuit a seep comes from and saves the time of checking each system in turn.
Both excite fluorescence. A UV lamp gives higher contrast in a dark environment and suits precise location; a blue lamp is easier on the eyes and carries more visible content, which suits fast wide-area scanning. In practice the two are often used together: scan with blue, then confirm details with UV.
It depends on the leak rate. An obvious leak can be found as soon as circulation is complete; a very small one may need the machine to run for hours or even a day or two, so that the tracer has time to pass through the seal gap. For difficult points, schedule a recheck on different shifts.
For a paper mill, the real threshold in fluorescent leak detection is not lamp brightness but three things: the right tracer for the medium, enough circulation time for the agent to reach the whole system, and a logbook entry for every leak found. Do those three and one dose covers the whole oil circuit, turning a search that once depended on stripping machines and luck into a routine job that fits inside a maintenance window. If you need a dosing plan based on system oil volume, medium type and site conditions, send us the equipment list and oil information and we will help calculate the quantity and the model.
This article belongs to the fluorescent leak detection technology section.
Other sections on the same product line are fluorescent leak detection (add a tracer, find the leak point with a UV lamp, locate before disassembly) and industrial test instruments (the entry point for UV inspection, speed measurement, stroboscopic observation and surface inspection).
Models mentioned in this article: LUYOR-6100, LUYOR-6200, LUYOR-6300. Ranges, accuracy and accessory lists for each model are given on the product pages.
Email: info@xinysun.com
Tel: 131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447