Overview
LUYOR-6200 is a water-based green fluorescent dye for leak detection and flow tracing, diluting from 1000:1 in a twin-neck bottle with a measuring chamber.
LUYOR-6200 is a water-based fluorescent tracer that mixes with water at any ratio. Add the right amount to a water system and let it mix with the flow, circulate, or spread naturally. Wherever a leak exists, the fluorescent solution seeps out and emits bright green fluorescence under a high-intensity UV lamp, so the leak point is easy to see.
Its value is not limited to finding leaks. As a water-soluble tracer it also works as a flow tracing tool: add it to a water source or a suspected source of contamination to follow the direction of flow, establish how lines are connected, and locate where a drain line runs and where it discharges. These two jobs often come together in boilers, heat exchangers, cooling water circuits, municipal drainage, and environmental investigations - locate the leak, then work out where the water goes.
The product suits new and existing systems alike and works in both static and circulating systems. Dilution is economical (1000:1 to 500:1, down to 5000:1 for pressure testing inside a closed vessel), and 500 ml covers a considerable water volume, which makes it a cost-effective routine method for water system leak detection.
Oil-soluble dyes cannot be used in water systems. They do not dissolve in water, so they float or cling, fail to reveal the leak, and contaminate the system. Equally, water-based products must not be added to oil circuits at random. The order of the decision is therefore to establish whether the medium is water or oil.
Water systems also pose a few specific difficulties, and these are where fluorescence works well:
Water is transparent, so a leak is hard to see - a small seepage evaporates or runs off quickly and leaves a damp ring with no clear point to locate. Fluorescent solution leaves a visible green trail.
The leak sits inside insulation, a buried pipe, or a jacket - the eye and a pressure test cannot point to the position directly, while the tracer seeps along the leak path to a surface you can observe.
A static system cannot be pressure tested - a pressure test on a tank, pool, or open system is impractical, while the tracer method works in a static system.
Welds and seals are the weak points - vessels such as power plant condensers and transformer tanks demand strict welding, and a small crack has serious consequences, yet their shape makes fluorescent magnetic particle testing difficult. Soaking the weld in tracer and then inspecting it is simpler and quicker.
| Item | Specification | Notes |
|---|---|---|
| Product model | LUYOR-6200 | Water-based fluorescent leak detection dye, LUYOR |
| Base type | Water-based | Mixes with water at any ratio |
| Fluorescence color | Green | LUYOR-6300 in the same range is blue; the color can be selected as needed |
| Excitation source | 365nm high-intensity UV lamp | LUYOR-365L fluorescent leak detection flashlight recommended |
| Recommended dilution | 1000:1 to 500:1 | Down to 5000:1 for immersion testing in a vessel |
| System type | Static or circulating water systems | New and existing systems |
| Mixing time | About 10-15 minutes in a circulating system | A static system needs a correspondingly longer standing time |
| Cleanup after the test | Rinse with clean water | Mixed solution can be reused |
| Storage | Sealed container, away from light | Mix a fresh batch when fluorescence drops |
The manufacturer's documents give the dilution both as 1000:1 to 500:1 and as 5000:1 to 500:1. The difference comes from the application: routine circulating leak detection starts at 1000:1, while immersion testing of a vessel can be diluted to 5000:1. Set the volume from the total water body and the fluorescence strength you need, and we can calculate it from your system volume.
| Order code | Package | Suited to |
|---|---|---|
| LUYOR-6200-00030 | 1 × 30 ml bottle | Small water systems, single low-volume checks |
| LUYOR-6200-00100 | 1 × 100 ml bottle | Equipment cooling water lines, a single heat exchanger section |
| LUYOR-6200-00240 | 1 × 240 ml bottle | Medium circulating water systems, checks rotating across several machines |
| LUYOR-6200-00500 | 1 × 500 ml bottle | Workshop-wide surveys, batch leak detection |
| LUYOR-6200-04000 | 1 × 4 L plastic pail | Large water systems, cyclic maintenance |
| LUYOR-6200-18000 | 1 × 18 L steel drum | Power plants, municipal networks, and long-term projects |
The 240 ml and 500 ml packs use a twin-neck bottle. The left side is a graduated measuring chamber: squeeze the bottle gently and the dye passes through a tube into the chamber, and you stop at the mark you need and pour it straight into the system. For a large volume, unscrew the right cap and pour directly. Dosing is accurate without a measuring cup, which makes the job easier on site.
Add the dye to the water at a dilution of 1000:1 to 500:1. Choose an inlet near the circulating pump or another point with good flow, so the dye mixes quickly.
In a circulating system, run the water normally for about 10-15 minutes so the dye mixes evenly. A static system needs a longer standing time, so the tracer reaches the leak path by natural diffusion and seepage.
Dim the ambient light and work along the pipes, joints, welds, and seals section by section with the LUYOR-365L. Bright green fluorescence marks a leak point; note the position and carry out the repair. Rinse with clean water when the check is complete.
A reading tip: a water-based solution runs down surfaces and forms a streak of fluorescence, and the leak itself is usually at the start of the streak or where trails converge, not at the far end. When a long trail appears, work upstream from it for a more accurate location.
Leak checks on boilers, heaters, heat exchanger coils, condensers, and storage tanks.
Seal checks on circulating water pumps, spray and sprinkler systems, and the associated fittings and valves.
Leak detection on pipe bodies, welds, and welded joints, and also flow testing and invisible marking.
Pipe tracing in power plants, leak detection in closed and cooling systems, and leak studies on industrial water lines.
Sewer infiltration testing, line location, illegal connection surveys, and storm and sanitary discharge analysis.
Lake, river, and pond analysis, pollution source tracing, and leak detection in fluid transfer systems.
The manufacturer's list of uses also covers plumbing and heating tracing, residence time studies, flow mapping and flow rate studies, and detection of sewer leaks that may reach ponds and reservoirs. Wherever you need to know where water comes from and where it goes, the tracer gives a direct answer.
Whether the unit is a power plant condenser or a transformer tank, welding requirements are strict, and a small crack can be fatal to the product. The shape of such vessels makes fluorescent magnetic particle testing difficult, but checking a weld with LUYOR-6200 is simple and quick:
Mix the fluorescent tracer with water at 5000:1, adjusting to the concentration needed. Use enough solution to submerge the weld being tested.
Pour the mixed solution into the vessel and leave it for 30 minutes to 1 hour. Where possible, apply light pressure to the solution inside the vessel for a better result.
Work carefully over the welded areas and the connections where a leak may occur with the LUYOR-365L. Bright yellow-green light confirms a leak at that point; mark the position.
Drain the solution into a designated container, repair the leak, then repeat the steps to confirm the repair. The vessel rinses clean with water, and the mixed solution can be reused.
When a mixed fluorescent solution is not in use, keep it in a container away from light. Before the next use, shine the UV lamp on the solution itself; if the fluorescence has dropped noticeably, mix a fresh batch. Otherwise a real leak can be missed because nothing shows under the lamp.
Start with the medium: an oil system takes 6100, and a water system takes either 6200 or 6300, chosen on fluorescence color and dose.
| Model | Base | Fluorescence color | Suited to |
|---|---|---|---|
| LUYOR-6100 | Oil-soluble | Yellow-white | Engine oil, hydraulic oil, fuel, transmissions, and other oil-phase systems |
| LUYOR-6200 | Water-based | Green | Routine water system leak detection and flow tracing, where strong green contrast reads directly |
| LUYOR-6300 | Water-based | Blue | Where blue fluorescence is needed or parallel lines need zone marking; 500 ml covers 3000 liters of water |
The systems covered by 6200 and 6300 are almost the same (boilers, heaters, pumps, sprinkler systems, storage tanks, piping, and the associated connections). The real difference is fluorescence color: 6200 green, 6300 blue. Color selection depends mainly on whether the system already contains interfering color, whether the tracer has to be distinguished from other marks, and how the people on site prefer to read the result.
Matching lamp: use the LUYOR-365L wide-area fluorescent leak detection flashlight for large-area scanning, and a standard UV flashlight for tight spaces or close spot checks. If your acceptance document sets an irradiance threshold at the inspection surface, add a UV radiometer for an on-site check.
No. LUYOR-6200 is a water-based product designed to mix with water; in an oil circuit it disperses poorly and will not reveal a leak. Use LUYOR-6100 for oil-phase systems. The test is simple: is the medium circulating in the system water or oil?
The two figures match different applications: routine circulating leak detection at 1000:1 to 500:1, and immersion testing of a vessel, such as a weld check, diluted to 5000:1. The principle is that the concentration needs to be high enough to make the leak visible. A stronger mix fluoresces more but costs more, while a mix that is too weak makes small leaks hard to identify. Tell us the total water volume and the system type, and we can calculate the quantity for you.
Rinsing with clean water is enough, with no special cleaning agent. If the system carries process circulating water, change the water as the process requires; for ordinary cooling or test water, rinse until the fluorescence is no longer visible.
Yes, but it must be stored in a container away from light. Before reuse, shine the UV lamp on the solution itself and mix a fresh batch if the fluorescence has clearly weakened. Do not stretch it, or a real leak can be read as no leak.
Yes. 6200 works in static systems too; mixing relies on natural diffusion, so allow a longer standing time and raise the concentration. In open vessels, concentrate the lamp on welds, flanges, and nozzles below the water line.
Yes, and that is one of its main uses. Add the product to a water source or a suspected source of contamination, then inspect the downstream outlets (drains, inspection chambers, discharge points) with the UV lamp. Whichever outlet shows green fluorescence is connected to that source. This is common practice for line location, illegal connection surveys, and storm and sanitary cross-connection checks.
The product is water-based and is used diluted at the ratio in the instructions. Wear gloves and safety glasses during handling, and avoid direct contact of the concentrate with skin or eyes. For environmental water studies, follow local discharge and testing regulations.
Price depends on the pack size and the accessories ordered, such as whether a LUYOR-365L lamp and safety glasses are included. Tell us the water system type, the total water volume, and the test method (circulating leak detection or immersion) through the form on this page or by phone, and we will return a dose calculation, a configuration, and a quotation. Stock is held in Shanghai, and an on-site demonstration can be arranged.
LUYOR-6200 product data and dilution notes
MSDS (Material Safety Data Sheet)
Illustrated guide to measuring with the twin-neck bottle
Procedure notes for weld testing on vessels
Dosing table calculated from total water volume
Notes on choosing between the water-based 6200 and 6300
Dilution calculated from water volume and test method
Water-phase versus oil-phase selection
Advice on green or blue fluorescence
Matching 365nm lamp and irradiance verification
Flow tracing plans and reading methods
Volume and project quotations, lead time confirmation
Send inquiry
Email: info@xinysun.com
Tel: 131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447