Xinysun Instrument (Shanghai) Co., Ltd.

Products

PRODUCTS

Breadcrumb: Home > Products > Industrial Test Instruments > Fluorescent Leak Detectors

LUYOR-6200 Water-Based Fluorescent Leak Detection Dye
  • LUYOR-6200 Water-Based Fluorescent Leak Detection Dye

  • LUYOR-6200 Water-Based Fluorescent Leak Detection Dye

  • LUYOR-6200 Water-Based Fluorescent Leak Detection Dye

LUYOR-6200 Water-Based Fluorescent Leak Detection Dye

Overview

LUYOR-6200 is a water-based green fluorescent dye for leak detection and flow tracing, diluting from 1000:1 in a twin-neck bottle with a measuring chamber.

Model:LUYOR-6200
Updated:2026-11-09
Manufacturer:LUYOR
Reference price:¥1,200
Views:
DetailsSend inquiry
Water-based formulamixes with water at any ratio, no contamination of the water system
Green fluorescencehigh contrast under a high-intensity UV lamp, leaks stand out
Dilution from 1000:1economical dose, 500 ml covers a large water volume
Twin-neck bottlebuilt-in measuring chamber, accurate dosing without a cup
Static or circulatingeffective in both still and flowing water systems
Reusablemixed solution keeps for the next job when stored in the dark

What LUYOR-6200 water-based fluorescent leak detection dye is

LUYOR-6200 is a water-based fluorescent tracer that mixes with water at any ratio. Add the right amount to a water system and let it mix with the flow, circulate, or spread naturally. Wherever a leak exists, the fluorescent solution seeps out and emits bright green fluorescence under a high-intensity UV lamp, so the leak point is easy to see.

Its value is not limited to finding leaks. As a water-soluble tracer it also works as a flow tracing tool: add it to a water source or a suspected source of contamination to follow the direction of flow, establish how lines are connected, and locate where a drain line runs and where it discharges. These two jobs often come together in boilers, heat exchangers, cooling water circuits, municipal drainage, and environmental investigations - locate the leak, then work out where the water goes.

The product suits new and existing systems alike and works in both static and circulating systems. Dilution is economical (1000:1 to 500:1, down to 5000:1 for pressure testing inside a closed vessel), and 500 ml covers a considerable water volume, which makes it a cost-effective routine method for water system leak detection.

Why water systems need a dedicated water-based dye

Oil-soluble dyes cannot be used in water systems. They do not dissolve in water, so they float or cling, fail to reveal the leak, and contaminate the system. Equally, water-based products must not be added to oil circuits at random. The order of the decision is therefore to establish whether the medium is water or oil.

Water systems also pose a few specific difficulties, and these are where fluorescence works well:

  • Water is transparent, so a leak is hard to see - a small seepage evaporates or runs off quickly and leaves a damp ring with no clear point to locate. Fluorescent solution leaves a visible green trail.

  • The leak sits inside insulation, a buried pipe, or a jacket - the eye and a pressure test cannot point to the position directly, while the tracer seeps along the leak path to a surface you can observe.

  • A static system cannot be pressure tested - a pressure test on a tank, pool, or open system is impractical, while the tracer method works in a static system.

  • Welds and seals are the weak points - vessels such as power plant condensers and transformer tanks demand strict welding, and a small crack has serious consequences, yet their shape makes fluorescent magnetic particle testing difficult. Soaking the weld in tracer and then inspecting it is simpler and quicker.

Core technical specifications

ItemSpecificationNotes
Product modelLUYOR-6200Water-based fluorescent leak detection dye, LUYOR
Base typeWater-basedMixes with water at any ratio
Fluorescence colorGreenLUYOR-6300 in the same range is blue; the color can be selected as needed
Excitation source365nm high-intensity UV lampLUYOR-365L fluorescent leak detection flashlight recommended
Recommended dilution1000:1 to 500:1Down to 5000:1 for immersion testing in a vessel
System typeStatic or circulating water systemsNew and existing systems
Mixing timeAbout 10-15 minutes in a circulating systemA static system needs a correspondingly longer standing time
Cleanup after the testRinse with clean waterMixed solution can be reused
StorageSealed container, away from lightMix a fresh batch when fluorescence drops

The manufacturer's documents give the dilution both as 1000:1 to 500:1 and as 5000:1 to 500:1. The difference comes from the application: routine circulating leak detection starts at 1000:1, while immersion testing of a vessel can be diluted to 5000:1. Set the volume from the total water body and the fluorescence strength you need, and we can calculate it from your system volume.

Pack sizes and order codes

Order codePackageSuited to
LUYOR-6200-000301 × 30 ml bottleSmall water systems, single low-volume checks
LUYOR-6200-001001 × 100 ml bottleEquipment cooling water lines, a single heat exchanger section
LUYOR-6200-002401 × 240 ml bottleMedium circulating water systems, checks rotating across several machines
LUYOR-6200-005001 × 500 ml bottleWorkshop-wide surveys, batch leak detection
LUYOR-6200-040001 × 4 L plastic pailLarge water systems, cyclic maintenance
LUYOR-6200-180001 × 18 L steel drumPower plants, municipal networks, and long-term projects

The 240 ml and 500 ml packs use a twin-neck bottle. The left side is a graduated measuring chamber: squeeze the bottle gently and the dye passes through a tube into the chamber, and you stop at the mark you need and pour it straight into the system. For a large volume, unscrew the right cap and pour directly. Dosing is accurate without a measuring cup, which makes the job easier on site.

Three-step operation

1
Add it to the system at the calculated ratio  

Add the dye to the water at a dilution of 1000:1 to 500:1. Choose an inlet near the circulating pump or another point with good flow, so the dye mixes quickly.

2
Circulate or let it stand to mix  

In a circulating system, run the water normally for about 10-15 minutes so the dye mixes evenly. A static system needs a longer standing time, so the tracer reaches the leak path by natural diffusion and seepage.

3
Inspect under the UV lamp  

Dim the ambient light and work along the pipes, joints, welds, and seals section by section with the LUYOR-365L. Bright green fluorescence marks a leak point; note the position and carry out the repair. Rinse with clean water when the check is complete.

A reading tip: a water-based solution runs down surfaces and forms a streak of fluorescence, and the leak itself is usually at the start of the streak or where trails converge, not at the far end. When a long trail appears, work upstream from it for a more accurate location.

Typical applications

Boilers and heat exchange equipment

Leak checks on boilers, heaters, heat exchanger coils, condensers, and storage tanks.

Pumps and sprinkler systems

Seal checks on circulating water pumps, spray and sprinkler systems, and the associated fittings and valves.

Piping and welds

Leak detection on pipe bodies, welds, and welded joints, and also flow testing and invisible marking.

Power plant and industrial water

Pipe tracing in power plants, leak detection in closed and cooling systems, and leak studies on industrial water lines.

Municipal and sewer networks

Sewer infiltration testing, line location, illegal connection surveys, and storm and sanitary discharge analysis.

Environmental and water body studies

Lake, river, and pond analysis, pollution source tracing, and leak detection in fluid transfer systems.

The manufacturer's list of uses also covers plumbing and heating tracing, residence time studies, flow mapping and flow rate studies, and detection of sewer leaks that may reach ponds and reservoirs. Wherever you need to know where water comes from and where it goes, the tracer gives a direct answer.

Weld testing on vessels

Whether the unit is a power plant condenser or a transformer tank, welding requirements are strict, and a small crack can be fatal to the product. The shape of such vessels makes fluorescent magnetic particle testing difficult, but checking a weld with LUYOR-6200 is simple and quick:

1
Mix the solution  

Mix the fluorescent tracer with water at 5000:1, adjusting to the concentration needed. Use enough solution to submerge the weld being tested.

2
Fill and let it stand  

Pour the mixed solution into the vessel and leave it for 30 minutes to 1 hour. Where possible, apply light pressure to the solution inside the vessel for a better result.

3
Inspect under the lamp  

Work carefully over the welded areas and the connections where a leak may occur with the LUYOR-365L. Bright yellow-green light confirms a leak at that point; mark the position.

4
Drain, repair, and re-check  

Drain the solution into a designated container, repair the leak, then repeat the steps to confirm the repair. The vessel rinses clean with water, and the mixed solution can be reused.

When a mixed fluorescent solution is not in use, keep it in a container away from light. Before the next use, shine the UV lamp on the solution itself; if the fluorescence has dropped noticeably, mix a fresh batch. Otherwise a real leak can be missed because nothing shows under the lamp.

Choosing among the three dyes

Start with the medium: an oil system takes 6100, and a water system takes either 6200 or 6300, chosen on fluorescence color and dose.

ModelBaseFluorescence colorSuited to
LUYOR-6100Oil-solubleYellow-whiteEngine oil, hydraulic oil, fuel, transmissions, and other oil-phase systems
LUYOR-6200Water-basedGreenRoutine water system leak detection and flow tracing, where strong green contrast reads directly
LUYOR-6300Water-basedBlueWhere blue fluorescence is needed or parallel lines need zone marking; 500 ml covers 3000 liters of water

The systems covered by 6200 and 6300 are almost the same (boilers, heaters, pumps, sprinkler systems, storage tanks, piping, and the associated connections). The real difference is fluorescence color: 6200 green, 6300 blue. Color selection depends mainly on whether the system already contains interfering color, whether the tracer has to be distinguished from other marks, and how the people on site prefer to read the result.

Matching lamp: use the LUYOR-365L wide-area fluorescent leak detection flashlight for large-area scanning, and a standard UV flashlight for tight spaces or close spot checks. If your acceptance document sets an irradiance threshold at the inspection surface, add a UV radiometer for an on-site check.

Frequently asked questions

Can I add it to an oil circuit?

No. LUYOR-6200 is a water-based product designed to mix with water; in an oil circuit it disperses poorly and will not reveal a leak. Use LUYOR-6100 for oil-phase systems. The test is simple: is the medium circulating in the system water or oil?

How much should I add? The manufacturer's documents give several ratios.

The two figures match different applications: routine circulating leak detection at 1000:1 to 500:1, and immersion testing of a vessel, such as a weld check, diluted to 5000:1. The principle is that the concentration needs to be high enough to make the leak visible. A stronger mix fluoresces more but costs more, while a mix that is too weak makes small leaks hard to identify. Tell us the total water volume and the system type, and we can calculate the quantity for you.

Can the water in the system still be used after the test? Does it need a full flush?

Rinsing with clean water is enough, with no special cleaning agent. If the system carries process circulating water, change the water as the process requires; for ordinary cooling or test water, rinse until the fluorescence is no longer visible.

Can I keep mixed solution for the next job?

Yes, but it must be stored in a container away from light. Before reuse, shine the UV lamp on the solution itself and mix a fresh batch if the fluorescence has clearly weakened. Do not stretch it, or a real leak can be read as no leak.

A static system such as a pool or tank has no circulating pump. Can I still use it?

Yes. 6200 works in static systems too; mixing relies on natural diffusion, so allow a longer standing time and raise the concentration. In open vessels, concentrate the lamp on welds, flanges, and nozzles below the water line.

Can it trace the direction of flow and establish how lines are connected?

Yes, and that is one of its main uses. Add the product to a water source or a suspected source of contamination, then inspect the downstream outlets (drains, inspection chambers, discharge points) with the UV lamp. Whichever outlet shows green fluorescence is connected to that source. This is common practice for line location, illegal connection surveys, and storm and sanitary cross-connection checks.

Does it affect people or the environment?

The product is water-based and is used diluted at the ratio in the instructions. Wear gloves and safety glasses during handling, and avoid direct contact of the concentrate with skin or eyes. For environmental water studies, follow local discharge and testing regulations.

How are price, stock, and accessories handled?

Price depends on the pack size and the accessories ordered, such as whether a LUYOR-365L lamp and safety glasses are included. Tell us the water system type, the total water volume, and the test method (circulating leak detection or immersion) through the form on this page or by phone, and we will return a dose calculation, a configuration, and a quotation. Stock is held in Shanghai, and an on-site demonstration can be arranged.

Documents and support

Documents available on request

  • LUYOR-6200 product data and dilution notes

  • MSDS (Material Safety Data Sheet)

  • Illustrated guide to measuring with the twin-neck bottle

  • Procedure notes for weld testing on vessels

  • Dosing table calculated from total water volume

  • Notes on choosing between the water-based 6200 and 6300

Support

  • Dilution calculated from water volume and test method

  • Water-phase versus oil-phase selection

  • Advice on green or blue fluorescence

  • Matching 365nm lamp and irradiance verification

  • Flow tracing plans and reading methods

  • Volume and project quotations, lead time confirmation

Send inquiry

Message

  • Product Name:

  • Company:

  • Your Name:

  • Phone:

  • Email:

  • Province / Region:

  • Address:

  • Message:

Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.