Xinysun Instrument (Shanghai) Co., Ltd.

Applications

Breadcrumb: Home > Applications > Lab Research

GFP Fluorescence Primary Screening of Transgenic Adventitious Roots: How to Use a 365nm Blacklight

Updated:2026-11-02Views:

Screening transgenic material often starts with PCR, yet live, non-destructive fluorescence observation that gives an answer on the spot frequently saves more time. A 2026 radish sucrose paper in Plant Physiology and Biochemistry placed adventitious roots under a LUYOR-3105 UV lamp, picked the GFP-fluorescent roots immediately, and sent them on to RT-qPCR for confirmation. This article breaks that step down: why a 365 nm blacklight can reveal GFP, how to illuminate the material, how to choose between 365 nm UV and blue excitation, and where false positives and false negatives come from. It closes with a five-step bench procedure and a model selection table.

Many people start with PCR when screening transgenic material, but fluorescence observation - live, non-destructive, with an answer on the spot - is often the gate that saves the time. A 2026 paper on radish sucrose metabolism in Plant Physiology and Biochemistry placed adventitious roots transformed via Agrobacterium rhizogenes under a LUYOR-3105 UV lamp (365 nm), picked the GFP-fluorescent roots on the spot, and then ran RT-qPCR for confirmation. The original text is explicit: The transgenic adventitious roots were identified by LUYOR-3105 UV lamp and verified by RT-qPCR analysis; the results section likewise states that the adventitious roots showed GFP fluorescence under the LUYOR-3105 UV lamp. This article unpacks that step: why a 365 nm blacklight can show GFP, how to illuminate the material, how to weigh it against blue excitation sources, and where false positives and false negatives come from.

1. What the paper did

The work was carried out by the Zhejiang Institute of Subtropical Crops together with the Jiangsu Coastal Area Institute of Agricultural Sciences and the Hebei Academy of Agriculture and Forestry Sciences (Ying et al., Plant Physiology and Biochemistry, 2026). The subject was sucrose accumulation in the radish storage root: using a high-sugar cultivar "QX" and a low-sugar cultivar "HG" for targeted sugar metabolomics and transcriptomics, the authors identified an RsNF-YA6-RsSUS2 regulatory module - the transcription factor RsNF-YA6 binds the RsSUS2 promoter and represses it, and overexpression in Arabidopsis and radish raised sucrose content significantly.

The plant material for functional validation was produced as follows. Arabidopsis went through floral dip, with MS medium plus 36 mg/L hygromycin used to select T3 homozygous lines (OE-1/2/3). Radish went through Agrobacterium rhizogenes MSU440-mediated adventitious root transformation - pCAMBIA1300-RsNF-YA6 was introduced into A. rhizogenes, which then infected derooted "LHZ" seedlings to induce transformed adventitious roots.

Once those roots had formed, identification did not start with PCR but with fluorescence observation: the construct carries a GFP reporter, so roots placed under the LUYOR-3105 UV lamp that emitted green fluorescence were provisionally scored as positive transformants, and material was then taken for RT-qPCR to confirm expression level. The core data in the paper rest on this screen as well - sucrose content in adventitious roots of the overexpression lines was significantly higher than in the MSU440 empty-vector control.

2. Why a 365 nm blacklight can reveal GFP

GFP has two absorption peaks: a major peak near 395 nm on the UV side and a minor peak near 475 nm on the blue side. 365 nm sits on the excitation shoulder to the left of the major peak - photon energy is sufficient but excitation efficiency is below the peak, which means you can see it, just not as brightly as under blue light. Screening GFP with a blacklight relies on the qualitative present/absent criterion, and that is enough for a primary screen.

For this job a 365 nm blacklight also has a few convenient properties:

  • Relatively clean background. Plant tissue shows red chlorophyll autofluorescence under UV, but in non-green tissue such as roots this causes little interference, so the green GFP signal stands out.
  • No UVB or UVC. Output is confined to a narrow 360-370 nm band, without the 254/302 nm dose that damages living seedlings, so a few seconds of illumination does not affect subsequent culture.
  • Cold light, instant on. Screening happens at the pace of picking a lamp up and shining it - no warm-up, and no heating of the Petri dish.

3. The transformation and screening workflow in the paper

StepPracticeNotes
Vector constructionRsNF-YA6 CDS (terminator removed) ligated into pCAMBIA1300 and transformed into A. rhizogenes MSU440The vector carries a GFP reporter, so transformed roots fluoresce
Inoculation materialDerooted "LHZ" radish seedlings; adventitious roots induced after infectionA. rhizogenes-mediated, no tissue-culture regeneration required
Fluorescence pre-screenAdventitious roots observed under LUYOR-3105 (365 nm, 5 LEDs, about 7000 μW/cm² at 38 cm)Green-fluorescing roots are provisionally scored as positive
Molecular confirmationPositive roots sampled for RT-qPCR to confirm RsNF-YA6 expressionFluorescence is qualitative, expression level is quantitative
Functional validationSucrose content measured in overexpression roots and compared with the MSU440 empty controlSucrose rises significantly in OE roots, pointing to RsSUS2 repression

The key design of this workflow is two gates: the fluorescence pre-screen is fast, non-destructive, and lets the plant go back to culture; qPCR provides accuracy. Fluorescence removes most empty transformants, so PCR handles nothing more than the small set of remaining candidates - an order of magnitude less work.

4. How to run a blacklight screen: five steps

  1. Dim the room. GFP fluorescence is weak on its own and hard to resolve in a brightly lit laboratory. Close the blinds or move to a dark room, let your eyes adapt for a few seconds, and the signal becomes clear.
  2. Wear protective glasses. Intense 365 nm UV is a cumulative hazard to the eyes, so wear UV-blocking glasses while working; for photographs, add a yellow filter to suppress purple stray light.
  3. Fix the distance and sweep in zones. With a large-area model such as the LUYOR-365L, the effective area at 38 cm is about 200 mm, enough to cover a whole Petri dish rack or a row of culture vessels in one pass; sweep zone by zone. Portable models are held close to a single seedling.
  4. Keep a negative control. Place non-transformed roots from the same batch in the same field of view - "brighter than the control" is the criterion, not "looks slightly green".
  5. Mark positives immediately and confirm soon. Fluorescence observation does not harm the plant, but marking must be quick to avoid mixed vessels later; sample at least 20% of each batch for RT-qPCR, and validate everything when the system is new.

5. Choosing between 365 nm UV and blue excitation

For the same GFP screen, a 365 nm blacklight and a 440-460 nm blue excitation source (such as the LUYOR-3415RG) each have their place:

Dimension365 nm blacklight440-460 nm blue excitation source
Excitation positionExcitation shoulder left of the 395 nm major peak; lower efficiency, weaker signalNear the 475 nm minor peak; higher efficiency, brighter signal
Reading methodVisual qualitative present/absent judgmentViewing glasses allow weak-signal reading and photographic records
Effect on living materialNo harm with short exposure; cumulative phototoxicity over long exposureLow phototoxicity, suitable for prolonged observation
VersatilityLeak detection, penetrant inspection, fluorescence viewingDesigned for fluorescent protein observation
Typical useOn-the-spot pre-screen of large batchesConfirmation where photos and weak signals must be documented

In practice the two are a relay, not an either-or: the blacklight sweeps several hundred seedlings beside the culture rack and circles the positives, then the circled material goes under a blue source for a closer look and a photo record. If a qualitative screen is all the experiment needs and a blacklight is already on the bench, running it beats buying more equipment.

6. Where false positives and false negatives come from

Both directions of error exist in a fluorescence pre-screen, which is why the paper uses qPCR as a backstop:

  • False positives: yellow-green contaminant fluorescence (slide mounting medium, label paper, some medium components) also glows under UV, and red chlorophyll fluorescence can be mistaken for green GFP. Countermeasures - keep non-transformed controls in frame and re-check suspect samples under blue light.
  • False negatives: early roots with low expression, immature fluorescent protein (newly transformed roots need a few more days of culture for the chromophore to fold), and ambient light that overwhelms the signal. Countermeasures - allow enough expression time before screening and work in a darkened area.
  • Decay and photobleaching: holding the lamp on one spot too long dims the fluorescence. Look, mark, move on - do not burn a single point with the lamp.

7. Choosing within the blacklight family

The 365 nm blacklights offered on this site fall into four groups by application; for a GFP pre-screen the 365L and the 3180 are the ones to consider:

ModelFormIntensity / coverage (38 cm)Typical use
LUYOR-365LLarge-area handheld, multiple 365 nm LEDsAbout 6500 μW/cm², about 200 mm areaSweeping whole racks of culture vessels or dishes, zone by zone
LUYOR-3180Portable flashlight, concentrated spotHigh intensity at a fixed pointClose-up inspection of a single seedling or dish, carried on the person
LUYOR-2130LPortable blacklightFixed pointDegreasing checks, small-area fluorescence viewing
LUYOR-3103/3115Inspection lamp / hanging typeFrom 4500 μW/cm²Mainly industrial work such as fluorescent magnetic particle inspection

For large screening batches with many vessels, a large-area model such as the 365L is more efficient; for the occasional dish, a flashlight such as the 3180 is enough.

8. What else this pattern can screen

The "live fluorescence pre-screen plus PCR confirmation" framework is not limited by species, but by how visible the reporter is:

  • Hairy roots and adventitious roots: K599- and MSU440-mediated transformation systems with GFP or mCherry markers follow the same method as this paper; see the earlier articles on eGFP screening of hairy roots and positive selection of soybean hairy roots.
  • Transgenic seedlings: whole-plant screening of Arabidopsis and tobacco T0/T1 seedlings, a live check that complements hygromycin resistance.
  • Colonies and callus: picking fluorescent colonies and transformed callus clumps follows the same logic.

The difference lies in the excitation band: for qualitative screening where cost matters, a blacklight is sufficient; for photo records and weak-signal reading, move up to a blue excitation source.

9. Further reading

The full dataset for the radish RsNF-YA6-RsSUS2 pathway is in the original paper (Ying et al., Plant Physiology and Biochemistry, 2026, titled Integrated multi-omics revealed that the RsNF-YA6-RsSUS2 pathway regulates sucrose content in fleshy taproot of radish). If you are unsure about equipment selection or a screening protocol, tell us the material type, vessel format, and batch size and we can check the wavelength band and working distance together; you can also reach us through Contact us.

Related sections and models

This article belongs to the Laboratory research techniques section.

Other sections on the same product line include 365 nm blacklights (UV area sources for penetrant inspection, leak detection, and fluorescence checks - read irradiance, not wattage), GFP fluorescence flashlights (models sorted by GFP/RFP/DsRed band, handheld and benchtop), and Life science instruments (the entry point for fluorescence imaging, UV crosslinking, UV transmission, and cell irradiation).

Models mentioned in this article: LUYOR-3105, LUYOR-365L, LUYOR-3415RG. Ranges, accuracy, and accessory lists for each model are listed on the product pages.