Xinysun Instrument (Shanghai) Co., Ltd.

Applications

Breadcrumb: Home > Applications > Lab Research

LUYOR-3415RG Application: eGFP Colony Fluorescence Counting in a 2025 Nature Study on Alfalfa

Updated:2026-11-12Views:

Legumes both host rhizobia and resist pathogens, and the mechanism that balances the two is a central question in plant-microbe interaction. A 2025 Nature study from Wang Ertao's group identified MtLICK1/2, showing how it partners with MtLYK3 to amplify symbiotic signalling while suppressing immunity in the infection zone. This article focuses on one step of the immunology work - counting fluorescent bacterial colonies on plates - and sets out the role of the 3415RG in that step, the observation settings that matter, and the controls that keep the count honest.

Legumes can live in mutualistic symbiosis with rhizobia and still resist pathogen infection - the mechanism behind this symbiosis-immunity balance is a core question in plant-microbe interactions. A study published in Nature in May 2025 (Wang Ertao's group, CAS Center for Excellence in Molecular Plant Sciences) identified the cytoplasmic kinase MtLICK1/2 and showed how it cooperates with the nod factor receptor MtLYK3: on one side the two transphosphorylate each other and amplify symbiotic signalling, on the other they suppress plant immunity in the rhizobial infection zone. In the immunology experiments of this study there is an unremarkable but critical step - counting green-fluorescent colonies on culture plates - and it was carried out with the LUYOR-3415RG dual-wavelength fluorescence protein excitation source. Following the study's workflow, this article explains how fluorescence counting is used in plant-bacteria interaction experiments.

1. The paper at a glance: what the discovery of MtLICK1/2 means

Using the intracellular domain of MtLYK3 as bait, the team screened a cDNA library from the roots of Medicago truncatula inoculated with Sinorhizobium meliloti 1021 and found a strong interactor, named MtLICK1; its homolog MtLICK2 also interacts with MtLYK3, while neither MtLICK1/2 interacts with MtNFP or MtDMI2 - that specificity places MtLICK1/2 squarely on the MtLYK3 signalling pathway.

  • Transphosphorylation: during symbiosis MtLICK1/2 and MtLYK3 transphosphorylate each other, and phosphorylated MtLYK3 activates the receptor-like kinase MtDMI2, passing the symbiotic signal downstream;

  • Mutant phenotype: Mtlick1/2 double mutants (Tnt1 insertion lines NF9810/NF4329 in the R108 background) show defects in rhizobial infection and nodule development, matching the Mtlyk3-1 phenotype;

  • Immunosuppression: MtLICK1/2 is activated in the rhizobial infection zone and suppresses MAPK activation, the reactive oxygen species (ROS) burst and expression of immunity-related genes - the direct answer to how a plant tolerates a symbiont without losing its defence.

The immunosuppression half of the conclusion rests on a set of bacterial growth experiments: the more plant immunity is suppressed, the more pathogen grows. And the readout of "how much" comes from eGFP colonies on plates.

2. What the 3415RG does in the experiment

The immunology experiments used eGFP-labeled Ralstonia solanacearum and compared bacterial load among alfalfa genotypes by co-inoculation:

  • Inoculum preparation: R. solanacearum was grown in phi medium, washed and resuspended, and adjusted to OD600 0.02;

  • Co-inoculation: Medicago truncatula was grown on BNM medium for 4-5 days, the root was pierced 2cm from the tip with a sterile needle, and Nod factor plus inoculum were applied on a 3mm×4mm filter paper; the control replaced Nod factor with H2O;

  • Recovery and counting: at 5 days after inoculation (5 dpi) root segments were ground, resuspended in sterile water, serially diluted and plated on phi medium, then incubated at 28℃ for 48 hours;

  • Fluorescence counting: colonies of the eGFP-labeled strain were counted under the LUYOR-3415RG fluorescence protein excitation source.

The logic is plain: Nod factor pre-activates the plant's immunosuppression program, so the pathogen multiplies more in the root; in Mtlick1/2 mutants that suppression is broken and the recovered load drops. Each green-fluorescent colony on the plate is a quantitative readout of how strongly immunity was suppressed. 3. Why this kind of counting uses a fluorescence excitation source

Whole-plate scanning, no microscope stage to move. At a 150 mm excitation distance the spot is about 180 mm across, so a 9 cm Petri dish is covered in one pass and the eye can tell which colonies carry eGFP - whereas counting colonies under a fluorescence microscope means moving the stage back and forth to confirm each one, and a plate with several hundred colonies takes a long time.

Colonies are not disturbed. The excitation light passes through the dish, so colonies stay intact and can still be picked as positive single colonies for re-screening or liquid culture after counting.

Two wavelengths, two jobs. The standard LUYOR-3415RG combines an RB royal-blue channel (440-460 nm excitation, 500 nm emission) with a GR green channel (510-540 nm excitation, 600 nm emission): one matches GFP, eGFP and fluorescein, the other DsRed, tdTomato and mCherry. Change the reporter system and a switch selects the other channel, with no second instrument to buy.

Ready at the culture room bench. 27W total power from 12 LEDs means no darkroom is needed to excite; the 0.9kg body runs on battery, moves from the culture rack to the clean bench without effort, and does not have to be held by hand through a long screening session.

4. Operating points

  1. Dim the direct light: high output does not depend on a darkroom, but switching off direct visible light in the field of view further improves the contrast between GFP colonies and the medium, so weak expressors are less likely to be missed;

  2. Wear the right glasses: for GFP/eGFP use LUV-30A yellow fluorescence viewing glasses - they block the excitation light to protect the eyes and make green colonies stand out against a dark background;

  3. Fix the counting posture: keep excitation distance, illumination angle and scan path the same for every plate; write the counting rules (such as a minimum colony size) into the method in advance to reduce plate-to-plate subjectivity;

  4. Photograph for the record: when an image record is needed, fit the LUYOR light shield and fluorescence photo filter, lay the dish flat and hold the lamp head vertical to capture the whole plate in one frame;

  5. Set the controls: keep plates of the unlabeled strain and dilution plates from uninoculated roots alongside, to rule out false positives from medium autofluorescence and contamination.

5. Other typical uses in the same field

  • Colonization of GFP-labeled bacteria: use the excitation source for a fast pre-screen on whole roots and plates to locate the infection or colonization zone, then move to confocal microscopy for precise localization - the lamp covers speed, confocal covers detail;

  • Transgenic hairy root screening: on composite plants after Agrobacterium rhizogenes transformation, shine the source directly on the roots and pick GFP-positive roots for rhizobial inoculation; the method is described in fluorescence screening of transgenic hairy roots;

  • Colony counting in bacterial competition assays: for recovery counts with red markers such as mCherry, see the LUYOR-3421 benchtop excitation source protocol for bacterial competition experiments;

  • Positive screening of transgenic plants: identifying positive seeds and seedlings of rice, maize, soybean, cotton and Arabidopsis is a frequent use of this instrument in laboratories.

6. Frequently asked questions

What fluorescence do the two wavelengths of the LUYOR-3415RG show?

The standard unit has an RB royal-blue channel (440-460 nm excitation) for GFP, eGFP and fluorescein, and a GR green channel (510-540 nm excitation) for DsRed, tdTomato and mCherry. Two of five light sources - R, C, G, V and U - can be selected for factory assembly, and combinations for CFP, BFP, YFP or DAPI can be built, but the combination is fixed at the factory and cannot be changed in the field.

What advantage does it have over a fluorescence microscope for counting eGFP colonies?

Whole-plate scanning is fast, colonies are not disturbed, and the plate does not have to go onto a microscope. The advantage of a fluorescence microscope is subcellular localization, so for plate-level pre-screening and counting the excitation source is more efficient; the two are complementary.

Does it need a darkroom?

No. The 27W high-output lamp excites fluorescence under normal room light. When counting weakly fluorescent colonies, though, it helps to switch off direct light in the field of view and draw a blind, which improves contrast noticeably.

What accessories are needed for viewing and for photography?

For GFP viewing use LUV-30A yellow fluorescence glasses; for photography fit the LUYOR light shield and optionally a fluorescence photo filter such as LUV-495A to improve image quality. The standard package already includes two pairs of viewing glasses and an aluminum carrying case.

Plant material has autofluorescence - will it interfere with counting?

Chlorophyll autofluorescence sits mainly in the red part of the spectrum and has limited effect on GFP counting in the green channel; if root homogenate carries plant debris, background signal can appear. The standard practice is to include unlabeled-strain and uninoculated controls, and to fix the dilution and plating volume in the method.

How to choose between the LUYOR-3415RG and the 3421 benchtop source?

Look at the workstation: if you need to move by hand, illuminate whole seedlings or large dishes, and work in the field or greenhouse, choose the portable 3415RG; if the work sits on a bench with a stereo microscope for fine observation, choose the LUYOR-3421. Many laboratories run both, dividing pre-screening from close inspection.

Related products and further reading

Conclusion

This Nature study is a reminder that high-impact mechanistic conclusions often rest on plain methodological steps - count the eGFP colonies accurately and quickly, and the magnitude of immunosuppression becomes convincing. The value of a portable excitation source such as the LUYOR-3415RG is that it takes the fluorescence readout off the microscope workstation and turns it into a routine gesture at the bench. If you need to confirm a setup for a particular reporter system or strain, contact our technical team.

Source: Wang D, Jin R, Shi X, Guo H, Tan X, Zhao A, et al. A kinase mediator of rhizobial symbiosis and immunity in Medicago. Nature, 2025, 643(8072): 768-775. DOI: 10.1038/s41586-025-09057-0 (the full text is paywalled; the experimental details here are compiled from the public abstract, the figure legends and the manufacturer's published application notes, and the original paper takes precedence).

Related sections and models

This article belongs to the research laboratory techniques section.

Other sections on the same product line are GFP fluorescence flashlights (handheld and benchtop models sorted by GFP/RFP/DsRed band) and life science instruments (the entry point for fluorescence imaging, UV crosslinking, UV transmission and cell irradiation).

Models mentioned in this article: LUYOR-3415RG, LUYOR-3421, LUYOR-3260RB. Ranges, accuracy and accessory lists for each model are given on the product pages.

  • Official WeChat QR code

    Email: info@xinysun.com

  • Tel: 131-2093-6518

  • Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai

Official WeChat QR code Follow

Official WeChat QR code

Contact

131-2093-6518

Top