Views: Reflective tape is the reference mark a laser or photoelectric tachometer counts. Applied correctly it turns a spinning shaft into a clean pulse; applied badly it produces a reading that jumps, doubles or never appears. This page works through size, position, application, pulse-per-revolution setting and the order in which to chase a wrong number, then answers the twelve questions we are asked most often. The LUYOR RT12 pre-cut tab (12 × 12 mm, ten sheets of thirty) and the RT10/RT20 roll (10, 15, 20 and 80 mm widths) cover most measurements at ambient temperature.
Normal shaft diameter, working distance 0.3–1 m: a 12 × 12 mm pre-cut tab, one per revolution, PPR set to 1.
Large rotor, rough casting, wide spot or a distance beyond 1 m: cut a 20 mm strip from a roll, length 1.5–2 times the spot diameter.
Reading near a whole multiple of the true speed: count the marks and check the PPR setting before you suspect the instrument.
Occasional jumps or dropped counts at low speed: fit a fresh tab, mask any polished background with matte tape, then check sensor distance and angle.
A laser tachometer, a photoelectric speed sensor and a stroboscope do not observe rotational speed directly. They count returned light pulses: the mark sweeps through the spot once per revolution, the sensor emits one pulse, and the instrument converts pulse frequency into speed with RPM = pulse frequency (Hz) × 60 ÷ pulses per revolution. Intensity, size, number and position of the mark are four variables, and an error in any one of them shows up in the reading.
Paint and polished metal also reflect, but the returned intensity swings with angle and surface finish, the pulse width is inconsistent and low speeds drop counts. Glass-bead tape works by retroreflection: light returns along the incident path, so a usable signal survives several metres of working distance. That is why the tape holds its place on an industrial line.
The reflective area has to cover the whole spot with margin to spare. A working rule is a side length 1.5–2 times the spot diameter: the tab is half again to twice as large as the spot it has to catch.
| Working distance | Typical spot | Suggested tab size | Model |
|---|---|---|---|
| 0.1–0.5 m | 5–10 mm | 10 × 10 to 12 × 12 mm | RT12 pre-cut tab |
| 0.5–1 m | 10–15 mm | 12 × 12 to 20 × 20 mm | RT12, or RT10 at 15–20 mm width |
| 1–3 m | 15–30 mm | 20 × 30 mm or larger, strip preferred | RT20 at 20 mm, RT10 at 80 mm |
| Over 3 m | 30 mm or more | 80 mm strip, covering the visible arc | RT10 at 80 mm, cut to length |
Larger is not automatically better. The wider the mark, the more its edges feel airflow and centrifugal load at speed, and the more likely it lifts. Small shafts at high speed do better with a narrow 10–12 mm mark that keeps the whole spot inside the reflective area, which gives a cleaner pulse edge.
On a radius the spot actually sweeps. With the bracket mounted, use visible light to find where the spot lands on the shaft, then place the mark on that circle. Do not place it by eye.
Away from keyways, oil holes, balance weights, weld seams and cast bosses. These change the local radius, so the mark moves in and out once per revolution and the pulse spacing becomes uneven.
Small shafts: the end face comes before the barrel. An end face is flat, carries little centrifugal load and is easy to align. A mark on the barrel needs the sensor square to the surface; a small angle costs return light.
Face the sensor, incidence angle below about 30°. Retroreflection is angle-sensitive: the further off-axis the beam, the weaker the return, and the effect grows with distance.
One active mark per measuring surface. Mask other reflective features — nameplates, polished keys, reflective paint — with matte or black tape.
Clean. Wipe the oil film and dust off with anhydrous ethanol and let it flash off completely. Oil is the commonest cause of a lifted edge.
Position. Fix the location using the five points above, and dot the centre with a marker pen.
Press out the air. Work from the centre to the four edges and firm down the corners. A trapped bubble weakens the return locally.
Warm. Below 15 °C, warm both the tab and the surface to above 20 °C with a hot-air gun. A cold acrylic adhesive has little initial tack and the whole tab can come off.
Test at low speed. Jog the machine and confirm the reading is steady before running up to the working speed. Never make the first test at full speed.
Normal measurement takes one mark per revolution with the instrument set to PPR = 1. When you need several pulses per revolution, use a zebra pattern and set the PPR to the number of divisions rather than adding more tabs. Two 12 mm tabs make the reading close to twice the true speed, which is the most frequent false diagnosis of a failed instrument on site.
| Marking | Pulses per rev | PPR setting | Use |
|---|---|---|---|
| Single RT12 tab | 1 | 1 | Normal speed, direct reading |
| Single strip from a roll | 1 | 1 | Large diameter, long distance |
| Zebra tape, 36 divisions | 36 | 36 | Raising pulse density at low speed |
| Zebra tape, 120 divisions | 120 | 120 | Very low speed, stroboscopic fringe counting |
Work through consumable, mounting, sensor and instrument in that order. Most faults are settled at the first step.
| Symptom | Check first | Action |
|---|---|---|
| Reading about 2× or 3× true speed | Number of marks, PPR setting | Keep one mark, set PPR to 1 |
| No reading at low speed, dropped counts at high speed | Condition of the tab, reflective background | Fit a fresh tab, mask polished parts |
| Reading hunts within about ±5% | Spot drifting off the mark, incidence angle | Re-aim, shorten the distance |
| Tab keeps coming off | Application temperature, oil film | Degrease, warm, move to a high-temperature grade |
They work, and the test is a single question: does the instrument time the passage of a mark through its spot? Reflective tape is a consumable that is not tied to a brand. Handheld and bench laser or photoelectric tachometers from Fluke, Testo, ONO SOKKI, Shimpo, UNI-T, VICTOR, SATA, SMART SENSOR and Xinbao, and field balancers from CXBalancer, Schenck, VMI and PRÜFTECHNIK, all work on that principle and take our glass-bead tape directly. A few models set a minimum mark size; choose the size from the distance table in section 2.
Tape is a consumable, and the marks sold by instrument makers are the same class of glass-bead film, differing in size, adhesive and temperature limit. There is no need to hunt for a branded tab: selecting by working distance, application temperature and pulses per revolution is more reliable. Brand and trade names belong to their respective owners and are named here only to describe compatibility; no authorisation, distributorship or official supply relationship is implied.
For a one-off check, yes; for anything ongoing, no. Foil is a mirror: the return depends on angle, and a small sensor offset loses the signal. Paper is a diffuse surface with a return a fraction of the film's, so it fails as soon as distance grows. Neither has a uniform surface, so pulse width varies and low speeds drop counts. Long-term monitoring, high speed and long distance still call for glass-bead tape.
One per revolution for normal measurement. Two tabs of similar brightness on the same rotor produce two pulses per revolution, and with PPR at 1 the reading is close to double the true speed; three tabs triple it. When you need multiple pulses, switch to zebra tape and set PPR to the number of divisions.
No. A tab such as RT12 uses an ultra-thin backing, and one 12 × 12 mm piece weighs in the milligram range, negligible against a rotor of tens of kilograms. Balance is affected by placing the tape on a balance weight, or by stacking layers at a correction position. That is an application error, not a property of the tape.
Not advised. Once peeled, the adhesive picks up dust and loses tack, and a re-applied tab tends to lift and fly off at speed. Treat tape as a consumable and keep packs in stock rather than re-peeling.
A pulley yes, provided the tab sits on the solid face of the wheel rather than on the belt. A belt slips on the wheel, so the mark moves relative to the shaft and you read belt surface speed rather than a steady shaft speed. Gears and chains have gaps and relief that catch the spot; put the mark on the end face or on a smooth flange on the same shaft.
Paint is fine after degreasing and de-waxing. Rust and blasting are too rough: the tab cannot be pressed down and air creeps under the edges. Lay a strip of matte tape to level the area, then apply the reflective piece to that tape.
On a small shaft, use the end face. If the barrel is the only option, take a narrow 10 mm grade and run it around the circumference so the mark bends in one direction only. Press firmly: a curved surface springs back and the edges lift over time. Replace the tab once lifting starts.
It depends on tab size, sensor range and airborne dust. With a 12 × 12 mm tab, most laser tachometers are steady inside 1 m. Beyond 3 m, move to a 20–80 mm strip and make sure the spot stays inside the mark. Do not try to hold a long distance by winding up sensitivity; enlarge the mark instead.
The problem at low speed is too few pulses: the instrument does not see enough edges within its refresh period. Raise the pulses per revolution with a 36 or 120 division zebra pattern or a divided disc, and set PPR to match. Do not compensate with a multiplier, which amplifies noise pulses along with the signal.
Glass beads retroreflect from either face, so there is no strict direction. The edge orientation relative to rotation does affect pulse width: a strip laid along the circumference gives tidy edges and a cleaner pulse, while a strip laid across it tends to produce pulses of varying width.
Degrease before applying. For routine care, wipe the surface with a lint-free cloth and ethanol; the film is water-resistant and wiping does not damage the reflective layer. A persistent oil film weakens the return, which shows up as occasional jumps. Replacing the tab is more effective than adjusting the instrument.
RT12 comes as ten sheets of thirty tabs, 300 in a pack. At one or two tabs per machine per month, a production line uses one or two packs a year. Keep one pack of RT12 plus a roll of 20 mm tape; between them they cover normal and long-distance work.
Ambient temperature, normal shaft, within 1 m: RT12 pre-cut tab, peel and apply, one per revolution.
Large diameter, rough surface, long distance or a size you cut yourself: RT10/RT20 roll in 10, 15, 20 or 80 mm width.
Mounting point above 100 °C for long periods: HTRT high-temperature tape, rated 120 °C continuous and 200 °C short-term.
Several pulses per revolution or a phase reference: RT-Steps zebra tape, stripe spacing 0.5–10 mm, discs divided 15, 36, 60 or 120 ways.
Three facts settle the model: how speed is measured (laser tachometer, photoelectric sensor or stroboscope), the working distance, and the temperature at the mounting point. Once those are fixed the choice is usually a single part number.
Related reading: reflective tape for tachometers | laser tachometers | tachometer sensors | tachometer and stroboscope FAQ: reading problems and output | bench tachometry above 10,000 rpm | 48 field questions on reflective tape | five-point buying checklist | non-contact speed measurement
To confirm size and quantity for a particular machine, contact Xinysun Instruments (Shanghai) Co., Ltd. through the contact page.
Email: info@xinysun.com
Tel: +86-131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447
SiteMap | Privacy Policy | FAQ