Breadcrumb: Home > Applications > Semiconductor Cleanroom
Updated:2026-11-17
Views: A cleanroom bench looks clean until a beam of side light sweeps across it, and then particles, fibers and fingerprints all appear. A surface inspection lamp does not form an image; it uses intense light with a controlled angle and spot to make contamination visible through scattering. Selection comes down to three questions: which wavelength band, which form factor, and whether the lighting technique is right. This article compares four current models - the 3318 benchtop diffusing panel, the 3325G portable lamp, the 3360G zoom flashlight and the 3320 parallel beam unit - and explains what grazing, normal and oblique illumination each reveal, from wafer particles to fingerprints and micro-scratches.
A cleanroom bench looks clean to the eye until a beam of side light sweeps across it, and then particles, fibers and fingerprints all appear - that is how a surface inspection lamp is used. It does not form an image; it throws a beam of intense light with a controlled angle and spot onto the surface so that contamination and defects show up through scattering. Selection comes down to three questions: which wavelength band, which form factor, and whether the technique is right. This article takes them in that order, with common questions at the end.
First, keep it separate from a UV flashlight: the MNT-365A UV flashlight looks for organic residues that fluoresce - oils and cleaning agent residue light up under UV-A - while a surface inspection lamp looks for physical defects that do not fluoresce: particles, scratches, fingerprints and burrs revealed by side light. The two checks are often used together and cannot replace each other.
The point of band selection is to make the contrast between defect and background as large as possible:
| Band | Character | What it suits |
|---|---|---|
| White light (400-760nm) | Color rendering close to daylight; both defect and base color are visible | Full visual inspection of machined parts, painting, printing and assembly, where color and overall appearance have to be judged together |
| Yellow-green (500-600nm) | Monochromatic narrow-band output; the eye is sensitive in this region and background interference is low | Particles and micro-scratches on wafers, cover glass, lenses and precision parts; long visual inspection sessions in a cleanroom |
| Yellow (530-670nm) | Free of the blue-violet and UV components that photoresist is sensitive to | Work areas for photosensitive materials such as photoresist (yellow rooms) |
LUYOR surface inspection lamps cover four working formats: the 3318 offers cool white or warm white with an optional green filter, the 3360G offers yellow-green, white and yellow, the 3325G is a dedicated yellow-green unit, and the 3320 provides green, white or yellow in a parallel beam. When in doubt, yellow-green is the wider compromise - it keeps high contrast without giving up color information the way pure green does.
| Model | Format | Light source and illuminance | Power and weight | Suits |
|---|---|---|---|---|
| LUYOR-3318 series | Benchtop (diffusing panel) | 24W; 3318W cool white about 59,000 lux@30cm, 3318Y warm white about 49,000 lux, green filter optional | Mains powered; fixed station | Batch appearance inspection at a fixed station: optical parts, machined parts, printed matter |
| LUYOR-3325G | Portable (handheld or on a stand) | 36W LED, 570-580nm yellow-green, wide and highly uniform output | 100-240V AC (GD version with lithium battery); 900g, 180×200mm | Wafer and carrier inspection (fits 1-18 inch), large-area cleanroom sweeps |
| LUYOR-3360G yellow-green surface inspection lamp | Flashlight (zoomable) | 20W; 3360G yellow-green about 280,000 lux@40cm (5cm spot), 3360W white about 130,000 lux, 3360Y yellow about 70,000 lux | 5000mAh lithium battery, 3-4 hours runtime; 340g | Narrow areas, field patrols, re-checking wafers and precision parts; aluminum body wipes clean easily |
| LUYOR-3320 parallel beam surface inspection lamp | Parallel beam (on a stand) | 10 LEDs through a linear lens produce a parallel beam, 8 degrees vertical / 60 degrees horizontal; green 530nm about 45,000 lux@30cm, white 400-760nm about 51,000 lux | 100-260V AC or built-in 24V lithium battery; 1kg, 270×72×65mm | Micro-scratches, Mura, dust and coating uniformity; a 30×1.5cm bar of light for scanning, several units can be linked |
In one line: the 3318 is a station lamp, the 3325G is a sweep lamp, the 3360G is a flashlight and the 3320 is a parallel-beam scanning lamp. The diffusing panel of the 3318 spreads light over a whole area, which suits laying the sample out and looking carefully; the zoom spot of the 3360G (5 / 10 / 50cm at 40cm) can be narrowed to find particles and widened to survey an area; the 3325G sits between them, with wide output for inspecting a whole wafer; the 3320 takes the parallel-beam route, with light skimming the surface at 8 degrees so that scattering from micro-scratches is easier to see, at the cost of an illuminated area that is only a 30×1.5cm strip, so scanning along a line is required.
With the same lamp, different techniques reveal completely different defects. The table below is organized by defect type:
| Defect type | Technique | Why it becomes visible |
|---|---|---|
| Particles, dust, lint | Parallel-beam grazing: the body almost touches the surface and is swept along a direction close to 180 degrees | Light is refracted and scattered by the particle into the eye, so the particle becomes a bright point against a dark background |
| Fingerprints, water marks, oil film | Normal illumination: the optical axis close to 90 degrees to the surface | The contamination layer has a different reflectance from the substrate, so reflected light returns as a bright patch or a hazy area |
| Scratches, pits, bubbles | View normally first, then re-check with the lamp at a 10-30 degree oblique angle | Scattering at the scratch edge is stronger away from the specular direction, so a sweep at an oblique angle makes it light up |
Field experience compresses to a short rule: grazing for particles, normal for fingerprints, oblique for scratches. Reaching a conclusion after a single sweep at one angle is a common cause of missed defects. For a more detailed breakdown of technique, see surface cleanliness inspection before coating and particle inspection on the inner walls of wafer carriers.
| Application | Technique | Points to watch |
|---|---|---|
| Particles on wafer surfaces | Grazing sweep plus small-spot re-check | Adhered dust and lint; rule out scratches before calling a particle |
| Wafer masks and photomasks | View the pattern area normally, then re-check at 15-30 degrees | Pinholes, missing corners, particles, hazy contamination |
| LCD panels, cover glass, lenses | Normal for fingerprints and water marks, oblique for scratches | Regular reflections from the coating and AF layer are normal; judge a defect by whether it is isolated and irregular |
| Metal parts and machined surfaces | Grazing for particles and burrs, normal for scratches | Polished surfaces reflect strongly, so keep the spot small |
| Paint and coating surfaces | Oblique sweep | Orange peel, particles, sags, pinholes |
| Routine cleanroom patrol | Switch technique by surface type, grazing before normal | Tool surfaces, walls, pass boxes; pair with the MNT-365A for a fluorescent residue check |
Particle inspection in the semiconductor industry is where this method is applied in most depth; for the choice of method and a re-check SOP, read the semiconductor particle detection topic and cleanroom tool maintenance patrol applications.
A UV flashlight illuminates organic residue that fluoresces (oils, fibers, cleaning agent residue) and depends on UV-A excitation; a surface inspection lamp illuminates physical defects that do not fluoresce (particles, scratches, fingerprints, burrs) and depends on side-light scattering. Cleanroom inspection usually sweeps for fluorescent residue with UV first, then checks physical defects with a surface inspection lamp; the two are complementary.
Two reasons. First, under a monochromatic narrow band (500-600nm) there is less background interference, so the contrast between particle and substrate is cleaner; second, the eye is sensitive in the yellow-green region, so the subjective brightness is higher at the same illuminance and long visual inspection sessions are less tiring. The advantage of white light is complete color information, which suits work where defects and color or overall appearance have to be judged together.
Choose by working format: for a fixed station where samples are laid out and studied, take the 3318 benchtop diffused lamp; for whole-wafer or large-area sweeping, take the 3325G portable lamp; for narrow areas, field patrols and zoomed re-checks, take the 3360G flashlight. Their band coverage differs, and they can also be configured as a set.
There is no single answer; it depends on illuminance, viewing distance, the contrast characteristics of particle against substrate, and the ambient light level. In practice, grazing illumination with a dark background is the precondition for small particles to appear; when validating capability, confirm on site with a reference block or a known sample, which is more reliable than reading a specification table.
Side-light methods depend on contrast against a dark background; the stronger the ambient light, the more easily a weak scattering signal is swamped. For cleanroom visual inspection, turn off or shield ambient light and let the observer adapt for a few minutes before judging; keeping the lighting conditions fixed for a given inspection item is what makes the criterion stable.
The LED life of the 3325G is rated above 50,000 hours, and for the 3360G and 3318 illuminance decay is likewise the practical criterion: replace the unit when illuminance falls to the point of affecting defect judgment, or when it is visibly dimmer than a new unit of the same model. Keep the lens clean day to day, because dust and fingerprints noticeably reduce effective output.
If what you need to find is micro-scratches and dust on a flat reflective surface - a polished wafer face, cover glass, a coated part, a ground surface - the LUYOR-3320 parallel beam surface inspection lamp is the usual starting point: 10 LEDs through a linear lens produce a parallel band of light, grazing at 8 degrees vertical, 45000 lux green at 30cm, with the beam not aimed into the eye. It can be mounted on a stand for continuous scanning at a fixed station, or several units can be linked to cover a large workpiece.
A surface inspection lamp is an instrument that forces defects out with light: the band sets the contrast ceiling, the form factor sets the working situation, and the technique decides what you can see. The three LUYOR models cover station, sweep and handheld formats, and on the band side white, yellow-green and yellow each have a place - once the type of object and the working format are fixed, selection is not difficult. The real skill is in the technique: complete the grazing, normal and oblique steps before drawing a conclusion.
This article belongs to the frequently asked questions section.
Other sections on the same product line include surface inspection lamps (low-angle side light that pulls particles, scratches and fingerprints out of the background) and industrial test instruments (the entry point for UV inspection, rotational speed measurement, stroboscopic observation and surface inspection).
Models mentioned in this article: LUYOR-3318, LUYOR-3325G, LUYOR-3360G. Ranges, accuracy and accessory lists for each model are listed on the product page.
Email: info@xinysun.com
Tel: 131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447