Views: Leak costs are not linear. A seepage gap widens as wear proceeds, so the later a leak is found the higher the cost of a single repair. This article separates early leak detection into three parts: how the cost curve of a leak is calculated, how small a leak fluorescent tracing can actually resolve, and how to put detection into the routine inspection plan with records that can be traced. It includes a tracer selection table for oil and water systems, the time windows for the five-step procedure, inspection intervals and the fields of a leak log, so a workshop can use it as a checklist.
Equipment does not start leaking on one particular day. It seeps, then drips, then sprays: the sealing lip wears a gap, the gap grows a little with every pressure and temperature cycle, and the leak rate rises non-linearly. The value of finding it early is therefore not the price of a drum of oil, but trading an unplanned stop for a planned one-hour job.
Fluorescent leak detection has a clear place in this. It turns finding the leak from a shutdown task - dismantling, pressure testing, brushing on soap solution - into a routine job that fits into the inspection plan and can be done while the machine runs. It depends on getting three things right: reading conditions, tracer selection, and the discipline of working and recording. The article takes them in that order.
The same leak costs very different amounts depending on when it is found. Split by the moment of discovery:
| Point of discovery | Typical evidence | Action and cost |
|---|---|---|
| Found in a planned inspection | Seepage, staining, a thin oil film; oil level almost unchanged | Change the seal or re-torque; a one-hour job, no loss of output |
| Found on a routine round | Oil level falling steadily, filters blocking often, local temperature rise | Planned stop, parts replacement, check for consequential wear |
| Shutdown after an alarm or abnormal noise | Oil mist spreading, bearing and shaft seal damage, system contamination | Unplanned stop, loss counted by the hour, including dismantling and cleaning |
| Found when the leak is already out of control | A whole batch contaminated, waste liquid escaping | A quality incident and a compliance incident together, with cleanup and corrective action |
The point of this table is the gap between the top two rows: a few months separate them physically, an order of magnitude separates them in cost. A leak accelerates itself - abrasive particles enter the gap with the oil, and a wider gap admits more particles. Early intervention moves the knee of the curve to the left.
Divide leaks into three grades by form and the response rhythm becomes clear:
| Form | Test | Risk | Suggested deadline |
|---|---|---|---|
| Seep | Oil film or stain on the surface, no dripping, level essentially unchanged | Particles enter the gap and wear accelerates | Put on the plan, fix at the next stop |
| Drip | Visible dripping, clear accumulation in the drip tray | Falling level, contamination, slippery floor | Schedule a stop within two weeks |
| Flow | Continuous flow, rapid change in pressure or level | Seized bearing, fire, spreading contamination | Stop and deal with it on shift |
Gas systems keep a different set of books, and the comparison is worth making. A compressed air leak leaves no oil trace: it is found by ear, by ultrasound or by flow accounting. Its cost follows a chain - leak flow (m³/min) × specific power of the compressor (about 6-7 kW/(m³/min) at 0.7 MPa) × annual running hours × electricity price. A 0.1 m³/min leak running 6000 hours at 0.7 CNY/kWh comes to 2500-3000 CNY a year in electricity; several dozen such points across a plant are a steady waste.
One point needs to be clear: fluorescence cannot find gas leaks. A fluorescent tracer has to be dissolved in a liquid and has to seep out with that liquid to show under a UV lamp; compressed air, steam and fuel gas belong to ultrasound and flow accounting instead. The right division of labour in a plant is gas to ultrasound, liquid to fluorescence: the two do not overlap.
The whole mechanism compresses into four stages:
Take the oil-soluble LUYOR-6100: excitation peaks at about 494nm and emission at about 535nm. A shift of some 40nm looks small, but in engineering it is what makes the method work - emission and excitation have to be separated so that a filter can block the excitation and let the fluorescence through to the eye. The UV filter in a leak detection lamp does exactly that: it stops visible violet above 400nm, the background darkens, and the fluorescence stands out.
This also explains a common misunderstanding: a lamp that looks more violet and brighter is not necessarily better for leak detection. Lamps at 395nm and above carry more visible light: the eye finds them bright, but what is bright is the background, and the contrast of the fluorescence drops.
Colour matters too. Photopic vision is most sensitive to yellow-green near 555nm, so tracers that fluoresce yellow-green (the colour of 6200 and 6100 under UV) look brighter and carry further under the same excitation; the blue fluorescence of 6300 is inherently dimmer to the eye. That is not a defect, because the purpose of blue is zoning - where several water circuits run in parallel in one workshop, colour separates the loops far more reliably than remembering positions.
The conclusion up front: fluorescence does not measure an instantaneous leak rate but the amount of dye accumulated on the leak surface. A reading is possible when the seeping liquid has left enough dye molecules on the surface, so sensitivity depends on three variables at once: concentration, time and viewing conditions.
| Method | Typical detectable level | Conditions and limits |
|---|---|---|
| Visual (white light) | Already dripping or flowing, several millilitres per hour or more | Needs an oil trace or wet mark thick enough to see; nearly useless on dark or oily surfaces |
| Soap bubble or smear test | Gas systems, of the order of 10⁻³ Pa - m³/s | Needs a shutdown and access to the leak; fails on micro-leaks and hidden locations |
| Fluorescent tracing | Readable once the leak surface has accumulated microlitres; refrigerant systems down to a few grams of refrigerant per year | Needs dosing and waiting; blind spots that light cannot reach are missed |
| Ultrasound | Gas leaks, depending on differential pressure and orifice size | Strong directional location, but poor at telling which medium is leaking |
| Helium mass spectrometry | Of the order of 10⁻⁹ Pa - m³/s | Costly, needs dedicated tooling, limited to laboratories and high-end manufacturing |
Note how the fourth row is worded: its sensitivity is not a fixed number but a cumulative process that grows with waiting time. The same 0.01 ml/h seep looks completely different after 10 minutes and after 2 hours. Hence the rule for scheduling: leave enough time between dosing and reading, otherwise a "no leak" result is a false negative.
Ranked by influence, the variables that decide the detection rate usually run: 1. ambient light (background brightness) > 2. excitation irradiance > 3. dye concentration > 4. waiting time. That is why switching off the workstation lights and hanging a blackout cloth usually does more than buying a brighter lamp.
The rule has no exceptions: the tracer must be fully miscible with the medium. Oil systems take an oil-soluble tracer, water systems a water-based one; the wrong choice wastes the work, because oil-soluble dye poured into a water tank merely floats or sinks, the fluorescence goes with the sediment, and nothing shows under the lamp.
| Model | System and fluorescence colour | Typical dose | Suitable systems |
|---|---|---|---|
| LUYOR-6100 | Oil-soluble, Solvent Red 175, yellow-white fluorescence under UV (excitation 494nm/emission 535nm); the oil looks orange-red in daylight | 0.5-2.5 ml per litre of oil (500-2500 ppm) | Hydraulic oil, lubricating oil, fuel, transmissions, compressors |
| LUYOR-6200 | Water-based, green fluorescence, miscible with water in any ratio | From 1000:1, dilutable to 5000:1 for pressure testing | Cooling water, circulating water, boilers, tanks, piping |
| LUYOR-6300 | Water-based, blue fluorescence, clearly distinct from 6200 | 500ml treats about 3000 litres of water | As above; used for zoning where several water circuits run in parallel |
| SPI-WGB/WGG | Spectroline water-soluble tracer, blue or green, filtered to 2 microns, NSF certified | According to the water/glycol system dilution ratio | Water, water/glycol and coolant systems |
Three hard limits apply when selecting a tracer:
Colour does not change the principle, but it changes the efficiency of reading: green (the 6200 family) is enough for a single system, and where several water or oil circuits run in parallel in one workshop, alternating blue and green lets one pass with the lamp show which loop belongs to which machine.
Reading conditions can borrow the established wording of NDT practice: UV-A irradiance not below 1000 µW/cm² and ambient white light held below 20 lx (the viewing conditions for penetrant and magnetic particle testing in ISO 3059 and GB/T 5097, which leak detection can follow). Below that irradiance the fluorescence of a seep is lost in the noise.
| Application | Suggested lamp | How to read |
|---|---|---|
| Whole pipe runs, whole machines | LUYOR-365L (about 6500 µW/cm² at the centre at 38cm, useful area about 200mm) | Sweep slowly at 30-40cm, overlapping the spot edge by 1/3 |
| Final judgement on fittings, valve stems, shaft seals | LUYOR-3180 (30000-40000 µW/cm² at 38cm, spot about 30mm) | Work at 10-20cm, dark-adapt before reading |
| Fixed stations, washdown areas | IP68 fixed installation lamp (such as LUYOR-BBMA) | Continuous illumination with a light shield |
Three things that are often overlooked: 1. dark adaptation - coming from a bright area into darkness, the eye needs 5-10 minutes to recover its sensitivity to weak fluorescence, so switch off and wait before reading;2. lens cleanliness - oil on the head filter absorbs UV and produces the classic "bright lamp, no fluorescence";3. eye protection - 365nm is UV-A, and prolonged close viewing requires UV safety glasses (LUV-10 or equivalent); there is no "just a quick look" exception.
| Step | Time window (running system) | Time window (static system) | Evidence to keep |
|---|---|---|---|
| Dose and penetrate | 5-10 minutes | 2-3 hours; overnight for a slow seep | Photo of the dosing tag, dose record |
| Illuminate and read | After 5-10 minutes of dark adaptation | As above | Photo of the leak location with a reference object |
| Repair and re-check | Immediately after repair | After repair, hold under pressure for over an hour | Before and after photos, one file per leak |
Do not copy a neighbour's interval; set it from three factors: medium pressure and temperature, the severity of the consequence, and whether the machine sits on the critical path. A workable starting point:
The log needs six fields at minimum; miss one and no trend is possible: machine number or system name, dosing date and quantity, tracer model and batch, leak location with photo, grade conclusion, repair and re-check dates. After six months it shows which machine keeps seeping and which location is the weak point in the design or the assembly, which is far more useful than assigning blame afterwards.
A simpler start is a kit: for oil systems LUYOR-6801 (LUV-100 leak detection lamp, 240ml of 6100 tracer, cleaner, safety glasses, dosing tags); for water systems LUYOR-6802 (green) or LUYOR-6803 (blue). Everything needed is in the case, so a crew can draw it and start work.
If the log shows three or more leaks at the same location within a year, the seal itself is rarely the cause; it is usually one of four root causes:
| Root cause | Site evidence | Direction |
|---|---|---|
| Assembly and tolerance | Several machines of the same model leak on the same side | Check alignment, face flatness and tightening sequence |
| Seal selection or material | Seals hardened, cracked or extruded | Re-select the material for the medium and temperature (NBR/FKM/PTFE) |
| Pressure pulsation and temperature rise | Leakage follows the duty cycle, with clear peaks and troughs | Check the accumulator, relief valve and cooling capacity |
| Particle contamination | Oil cleanliness outside the target ISO 4406 class | Filter, change the oil, keep the filler cap clean |
Read leak results alongside oil analysis and a three-level warning appears: Level 1 (a seep under UV, cleanliness normal) goes on the watch list and is fixed at the next stop; level 2 (the leak growing, cleanliness one class worse) calls for a planned stop; level 3 (dripping, with a temperature rise or noise) is handled on shift. The logic matches the condition monitoring framework of ISO 17359: leak detection is not a one-off yes/no judgement but a continuous correction of the machine's condition picture.
| Source | Appearance | How to rule it out |
|---|---|---|
| Residue from a previous check | Fixed location, sharp boundary, still faintly visible after wiping | Clean with solvent and illuminate again; see whether it returns |
| Assembly or rust-preventive oil | Spread in patches, unrelated to the leak path | Clean, run under pressure and watch whether it reappears at the joint |
| Autofluorescence of rubber and plastic | The whole part glows, the boundary following its outline | Change angle and distance; autofluorescence does not extend along the leak path |
| Cleaner or degreaser residue | Blue-white haze, widely spread | Rinse with water or the specified cleaner and look again |
| Ambient reflection | Moves with the lamp | Move the lamp; real fluorescence stays put |
| Excess concentration | Large areas glowing yellow-white, hiding the leak | Reduce the dose or change the medium and retest |
One action decides the reading: wipe, illuminate, look again. It counts as a leak when it reappears in the same place after wiping and follows the direction of flow.
| Case | Preferred | In support |
|---|---|---|
| Seepage in hydraulic or lube systems | Fluorescent tracing | Oil analysis (ISO 4406 cleanliness, spectroscopy) for the wear trend |
| Cooling and circulating water | Water-based fluorescent tracing | Pressure decay for quantitative confirmation |
| Compressed air, steam, fuel gas | Ultrasonic leak detection | Flow accounting, soap bubble location |
| Vacuum and ultra-high vacuum | Helium mass spectrometry | - |
| Fast screening on a production line | Fluorescent scan | Confirm suspect points with a high-intensity narrow beam |
Sources for the standards and methods (check the original by number; the current edition from the issuing body applies)
It depends on how much dye accumulates on the leak surface, so there is no fixed figure. With a 365nm high-intensity UV lamp and a sensible waiting time, a seep that has not yet formed a drop can be found (microlitres accumulated on the surface), and refrigerant systems can show a slow leak of a few grams per year. Below that level, laboratory methods such as helium mass spectrometry are needed.
In order of likelihood: 1. wrong tracer medium (oil-soluble dye in a water system, or the reverse); 2. not enough waiting time; 3. ambient light too strong; 4. oil on the head filter, or a violet torch with no filter at all; 5. dye concentration too low, or the product is out of date; 6. the leak sits behind insulation or a guard, where the light never reaches.
An oil-soluble dye such as LUYOR-6100 can stay in the system long term when dosed to specification; it does not change oil performance. After the leak is repaired, illuminate again directly, with no need to add more. If the system is sensitive to additives or an oil change is due, it leaves with the old oil.
Oil systems take 0.5-2.5 ml/L, so a 200L tank takes 100-500ml. Water systems start at 1000:1, and 500ml of concentrate covers hundreds to thousands of litres. For exact figures, calculate from system volume and pipe diameter.
No. A gas carries no liquid medium to hold the dye. Gas leaks are found with ultrasound, backed by flow accounting and soap bubble location; fluorescent tracing applies to systems with a closed circulating liquid.
Yes, but the detection rate drops. Sunlight and workstation lighting are the main interference; prefer dusk, night or a blackout cloth. Where light cannot be excluded, wear yellow contrast glasses and work as close to the surface as possible.
Further reading: Fluorescent leak detection explained: wavelength, sensitivity and 18 reading questions, Finding industrial leaks: lighting up the leak with the LUYOR-365L, Preventive maintenance on hydraulic systems: fitting fluorescent detection into the inspection plan, Finding equipment leaks in a paper mill.
This article belongs to the fluorescent leak detection section.
Other sections on the same product line include fluorescent leak detection (add a tracer, find the leak under UV, locate before dismantling), 365nm blacklights (UV area lamps for NDT, leak detection and fluorescence inspection, judged by irradiance rather than wattage), industrial test instruments (the entry point for the four lines: UV inspection, speed measurement, stroboscopic observation and surface inspection).
Models mentioned in this article: LUYOR-6100, LUYOR-365L, LUYOR-6200. Ranges, accuracy and accessory lists for each model are listed on the product pages.
Email: info@xinysun.com
Tel: 131-2093-6518
Address: 1525 Minqiang Road, Bldg 26, Songjiang, Shanghai
Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447