LUYOR-925 reads 0-99999 r/min at +/-0.05% with a 50 mm to 10 m laser range. 100 hour battery, +/-80 deg angle, BNC 0-5 V TTL output and 1/4-20 mount.

Model:LUYOR-925
Updated:2026-11-09
Manufacturer:LUYOR
Reference price:¥4,800
Views:
DetailsSend inquiry
0-99 999 r/min speed range
±0.05% of reading accuracy
50 mm - 10 m measuring distance
±80° working angle
100 hours continuous runtime
TTL / BNC signal output

Three Things That Actually Stop Speed Measurement on Site

Measuring the speed of rotating equipment is simple in principle; the difficulty is site conditions. Three obstacles come up in routine inspection:

Cannot reach it

The machine is up high, fenced off, hot on the outside, or there is nowhere to stand. An ordinary tachometer has to be held close, so many points get skipped, or the line has to stop and scaffolding go up before you can measure.

Cannot aim it

On densely packed trains the shafts sit close together, the shaft you want is on the far side, and there is no room to face the surface square on - and most tachometers are very sensitive to angle.

Cannot connect it

The moment speed has to go into a PLC or data acquisition system for logging and trending, you need a signal output. A tachometer without one leaves you copying numbers by hand.

The LUYOR-925 specifications are built around exactly these three: 10 m measuring distance solves reach, ±80° working angle solves aiming, and a standard BNC TTL output solves connection. Add 100 hours of runtime and a 1/4-20 tripod thread and it also handles fixed-mount, continuous-recording monitoring.

What it cannot replace: the LUYOR-925 is a field inspection and troubleshooting tool, not a metrology standard.

How It Works: Why It Still Reads Accurately in a Bright Shop

The logic of a laser tachometer is pulse counting: the laser hits reflective tape on the rotating part, one light pulse comes back per revolution, and the instrument counts pulses per minute and converts that to speed. One thousand return signals in a minute reads 1000 RPM.

High accuracy under interference: fixed-frequency emission plus filtered reception

The main interference on site is ambient light - shop lighting, daylight from skylights, indicator lamps on nearby machines - all of which reaches the receiver. The LUYOR-925 approach: an internal oscillator fires the 650 nm laser at a specific frequency, and the receiver filters for return light at only that frequency, rejecting ambient light at other frequencies. That is why it holds a stable reading in bright shops with densely packed machinery.

Long distance and wide angle: the large convex lens

A large convex lens sits in front of the receiving sensor and accepts laser light returned from almost 180° in front of the unit. That means the beam only has to land on the reflective tape; the body does not need to be square to the shaft. You can measure while holding the unit at an angle, even close to side-on.

StageImplementationSite problem it solves
Emission650 nm laser fired at a specific frequencyTags the return light so it can be separated from stray light
ReceptionFilter circuit detects only the emitted frequencyShop lighting, daylight and nearby light sources are rejected
OpticsLarge convex lens accepts return light over close to 180°Enables 10 m distance and ±80° handheld measurement
ConversionReflected pulses are counted into revolutions per minute0-99 999 r/min range, one sample every 0.5 s

Reflective Tape: Where Nine Out of Ten No-Reading Cases Come From

This is the step most often overlooked, and the one that most often leads to the instrument being blamed. A laser tachometer requires reflective tape on the target and requires that nothing else in the beam path reflects. Plenty of field reports of 'it will not measure' turn out to be tape problems, not instrument problems.

SituationTypical symptomCauseCorrect action
No reflective tape on the surfaceReading stays 0, or the digits jumpNo identifiable once-per-revolution pulseApply a strip of reflective tape where the laser can hit it
Polished shaft, chrome, oil filmReading runs high or jumps wildlySurfaces other than the tape also reflect and are counted as extra pulsesFirst lay a strip of matte non-reflective tape to suppress the background, then apply the reflective tape on top
Tape too small, dirty or curlingReads close up, loses data farther outReturn light too weak for the receiverReplace the tape; at longer distance use a larger patch, kept flat and well bonded
Curved surfaces, small shaft diametersData loss at speedTape not fully conformed, or edges liftingPress it down along the curve, with no bubbles or lifted edges
Rated 10 m but no reading on siteWorks close up, nothing at distanceStronger ambient light and wider angles both cut usable distanceConfirm a stable reading close in, then step back to find the usable distance at that site
One rule to remember: if it reads close up but not at distance, the return light is probably too weak (tape or site lighting). If it never reads at all, check first whether tape is fitted and whether the laser is on it. One roll of reflective tape is supplied; it is a consumable and can be replenished with your order.

Standard TTL Output: Getting Speed Into a PLC or Data Logger

Many users choose the LUYOR-925 because it includes a signal output as standard, with no extra option to buy. The output is a 0-5 V square wave (TTL level) on a standard BNC male connector, so it connects directly to:

Devices it connects to directly

  • PLC control systems: speed becomes a live operating parameter in control and monitoring

  • Data loggers / recorders: continuous speed curves for trend comparison and fault tracing

  • Host computers: with an acquisition card, for speed data storage and analysis

  • Stroboscopes with external trigger: speed signal triggers synchronized observation of the rotating part

Two things to confirm before wiring

  • Connector type: the instrument side is a BNC male. If your logger does not have a BNC input, an adapter cable is needed to bring out signal and ground; we can help confirm the wiring.

  • Level matching: the output is a 0-5 V square wave; confirm the input range of the acquisition port matches before connecting.

Together with the also-standard 1/4-20 tripod thread, that combination makes a low-cost on-line speed monitoring setup: the tachometer fixed on a stand aimed at the shaft, the BNC output feeding a logger, recording condition changes over time. If your tripod uses a 3/8 thread, add a 1/4-to-3/8 adapter head.

Power and Runtime: One Charge Covers a Week of Inspection

A built-in high-capacity Li-ion pack is rated for over 100 hours of continuous operation. At a routine of 1-2 hours of actual measuring per day, one charge covers a full week or more in the field, with no need to stock and swap disposable batteries the way alkaline-powered tachometers do.

For long on-line monitoring, connect the supplied 5 V DC charger and it runs continuously, 24 hours a day, with no battery limit. That matters for fixed-mount, continuous-recording work.

100 hours

Continuous battery operation, covering a week of inspection routine

24 hours

Continuous operation on the 5 V DC adapter, suited to on-line monitoring

0.5 s

Single sample time (above 120 r/min), measuring from switch-on with no warm-up

Housing Built for Site Conditions

  • Red 5-digit 7-segment LED display, 1 r/min resolution; LED digits read better than a plain LCD in dim areas

  • Aluminum body with polyester impact boot, 1 m drop tested, for frequent movement around a shop

  • IP40 rated: handles shop dust, but is not for washdown or high-humidity condensation

  • Press once to switch on: no need to hold the button; measuring continues after release

  • 350 g, 150 × 120 × 45 mm, one-handed operation

Applications and Typical Measuring Points

ApplicationWhat it doesTypical measuring points
General industrial equipment inspectionPeriodic speed checks to see whether a machine has drifted from normalMotor output shafts, fan impeller shafts, pump and centrifuge shafts, air compressors
Production line drivesVerify roller speed, find slip and stallShafts, drive rollers and pulleys on textile, paper, packaging and printing lines
Precision manufacturingSpindle speed checks and outgoing quality verificationMachine tool spindles, precision drive components
Automation and controlLive speed monitoring and data traceability with a PLC or loggerCritical rotating stations on a line, equipment needing continuous records
Equipment at height / high risk / high temperatureLong-distance measurement without stopping the line or approaching the machineFans at height, tower-mounted equipment, furnace areas, guarded machine trains
HVAC and construction machineryPreventive maintenance checks on rotating partsVentilation equipment, fans and drive parts on construction machinery
To be clear: the LUYOR-925 is positioned for field inspection and troubleshooting. For metrology acceptance where a calibration certificate is required, choose a model supplied with a NIST-traceable certificate so the data is accepted in audits.

Five Steps for Measuring Speed on Site

1
Confirm the measuring point and the safety conditions

Pick a shaft section you can safely illuminate, confirm your standing position and the surrounding conditions, and keep clear of rotating parts when measuring without stopping the line.

2
Apply reflective tape (the critical step)

Apply a strip of reflective tape at the measuring point and press it down. If the surface is highly reflective, lay matte tape first to suppress the background. Make sure nothing else in the beam path reflects.

3
Test close in and confirm a stable reading

Start by illuminating the tape from close range and confirm the reading is stable and not jumping, then step back gradually to find the usable distance under that site's lighting.

4
Read and record the speed

The display shows red 5-digit figures at 1 r/min resolution. Compare against the nameplate speed or historical records to judge drift. One sample takes 0.5 s.

5
Connect the signal output when needed

Use a BNC cable to bring the 0-5 V square wave to a PLC or logger for continuous recording; for long monitoring, fix the unit on a tripod and power it continuously from the 5 V DC adapter.

Laser safety: the LUYOR-925 uses a Class 2 low-power visible laser (650 nm, 1 mW maximum), compliant with IEC 60825-1:2001. Class 2 is a low-output visible laser where the blink reflex provides protection under normal use, but never look into the laser source and never aim it at anyone's eyes or at positions where others may look into it. Never aim the laser at mirrors or other highly reflective objects, so reflected light cannot reach the eye.

Specifications

The data below comes from the official product specification table and can be used directly for selection and internal approval:

ModelLUYOR-925
Measuring principleNon-contact laser photoelectric reflection, counting pulses reflected from reflective tape
Laser class and specificationClass 2 visible laser; 650 nm; 1 mW maximum; compliant with IEC 60825-1:2001
Speed range0-99 999 r/min
Accuracy±0.05% of reading ±1 digit
Display resolution1 r/min
Measuring distance50-10 000 mm
Working angle±80°
Sample time0.5 s (above 120 r/min)
DisplayRed 5-digit 7-segment LED
Signal outputBNC male connector; 0-5 V square wave (TTL level)
Power and runtimeBuilt-in Li-ion pack; over 100 hours continuous; 24 hours continuous on the 5 V DC charger
Mounting1/4-20 standard tripod thread on the back (3/8 tripods need an adapter head)
Body constructionAluminum body with polyester impact boot, 1 m drop tested
ProtectionIP40
Dimensions150 × 120 × 45 mm
Weight350 g
Operating temperature0-50 ℃
Storage temperature−10-+50 ℃
Relative humidity10%-90% RH (non-condensing)
Packaging dimensions450 × 280 × 150 mm
Standard packageTachometer main unit ×1, charger ×1, 1 roll reflective tape, manual, certificate of conformity, warranty card
The figures above are published nominal values. 10 m is the nominal maximum measuring distance; actual usable distance depends on site lighting, tape condition and measuring angle, and may be shorter. Small batch-to-batch differences occur; the manual shipped with the unit governs. For a formal datasheet for selection or internal approval, contact us.

FAQ

Why is reflective tape required on the target, and can it be skipped?

No, it is the measurement precondition for this type of instrument.The LUYOR-925 counts pulses: the laser hits reflective tape on the rotating part, one pulse comes back per revolution, and the instrument converts pulses per minute into speed.If there is no tape, or if surfaces other than the tape also reflect, it cannot separate one full revolution from other reflections, and the result is 0, no reading, or jumping digits.Apply a strip of reflective tape on the shaft surface and make sure nothing else in the beam path reflects.

The surface is bright, mirrored or oily and I cannot get a reading.What do I do?

Same principle: extra reflections are counted as extra pulses.On polished shafts, chrome parts, oil-film or highly reflective surfaces, first lay a strip of matte non-reflective tape to suppress the background, then apply the reflective tape on top of it, and the reading normally stabilizes.On curved surfaces or small diameters, make sure the tape conforms fully with no lifted edges.

The rating is 10 m.Does that mean every site measures at 10 m?

No.10 m is the nominal maximum under ideal conditions; usable distance is shorter, driven by three factors: stronger ambient light shortens range; smaller, dirtier or less flat tape weakens the return; and a wider angle between laser and surface weakens the return signal.Confirm a stable reading close in first, then step back to find the usable distance at that site.

The shop is brightly lit and sunlight comes in.Will that affect accuracy?

Not noticeably.The LUYOR-925 uses fixed-frequency laser emission with filtered reception: an internal oscillator fires the 650 nm laser at a specific frequency and the receiver detects only that frequency, filtering out stray light.The receiving sensor also has a large convex lens that accepts return signals over close to 180°.So it holds a stable reading under shop lighting and daylight; bright light only shortens usable distance.

What can the TTL output connect to, and what connector type is it?

The output is a 0-5 V square wave (TTL level) on a standard BNC male connector, and it connects directly to PLC control systems, data loggers, recorders, host computers, and stroboscopes with external trigger input.If your logger does not have a BNC input, an adapter cable is needed to bring out the signal; contact us and we will confirm the wiring.

Can it be used for long-term continuous on-line monitoring?

Yes.The back of the housing has a standard 1/4-20 tripod thread so the unit can be fixed on a stand aimed at the shaft for long observation, with the TTL output feeding speed continuously to a logger for trend records.A full Li-ion charge gives 100 hours; with the 5 V DC adapter it runs continuously for 24 hours.If your tripod uses a 3/8 thread, add a 1/4-to-3/8 adapter head.

How long does one full charge last?

The built-in high-capacity Li-ion pack is rated for over 100 hours of continuous operation.At 1-2 hours of actual measuring per day, one charge covers a week or more.The LUYOR-925 leads on distance, angle, runtime and standard signal output: 10 m reach, ±80°, 100 hours continuous, BNC TTL output as standard, 1/4-20 tripod thread as standard, aluminum body rated for a 1 m drop - suited to equipment at height or high risk, densely packed machine trains, and line inspection that must feed a PLC.For long distance, wide angle, connection to an acquisition system or long continuous monitoring, take the LUYOR-925; for the accuracy ceiling, surface speed or a calibration certificate, take the PLT200.

Can its readings serve as a metrology calibration basis?

The LUYOR-925 is positioned as a field inspection and troubleshooting tool at ±0.05% of reading ±1 digit, which suits judging drift from normal condition, trend comparison and inspection records.We can advise by application.

What happens when the tape runs out, and are there size requirements?

One roll is supplied; tape is a consumable and can be reordered as needed.Three points in use: match tape area to measuring distance, since longer distances need a larger, flatter reflective area; replace tape once it ages, collects dust or curls, because the return weakens noticeably; and place it where the laser can hit it close to perpendicular, to limit signal loss from a wide angle.We can supply matching reflective tape and matte base tape with your order.

Is it in stock in Shanghai, and can you arrange a demo or trial?

Xinysun Instruments (Shanghai) supplies LUYOR instruments and keeps stock; we can arrange an on-site demo and a trial on your actual application.Call 131-2093-6518, or leave your industry, the equipment to be measured and your contact details in the form at the bottom of this page.

Do I need to supply the reflective tape myself, and how often should it be replaced?

One roll is included; tape is a consumable and can be replenished with your order.Replace it when it is dirty, curled, visibly scratched or has gone dull.Longer measuring distances need a larger patch, kept flat and well bonded.Before applying, confirm that nothing else in the beam path reflects - on polished shafts, chrome parts and oil films, lay matte tape first to suppress the background, then apply the reflective tape on top.

Can it be mounted on a tripod for long-term on-line monitoring?

Yes.The 1/4-20 tripod thread is standard, so the unit can be fixed on a stand aimed at the shaft; with the standard BNC 0-5 V TTL output feeding a PLC or logger, that makes a low-cost on-line speed monitoring setup.For continuous running, connect the supplied 5 V DC adapter and it works 24 hours a day with no battery limit.If your tripod uses a 3/8 thread, add a 1/4-to-3/8 adapter head.

LED digits versus an LCD: are they readable in a shop?

The LUYOR-925 uses a red 5-digit 7-segment LED display at 1 r/min resolution.The digits are self-luminous, so they read clearly in dim shops and behind machines where a plain LCD struggles; LCDs also wash out in low temperature or direct light.

Can it be used where a calibration certificate is required?

Not on its own for metrology data.The LUYOR-925 is a field inspection and troubleshooting tool, supplied with a manual and certificate of conformity but no traceable calibration certificate.

Documents and Service

Documents available

  • LUYOR-925 official datasheet and manual

  • Tachometer comparison table (LUYOR-925 / PLT200 / PT99)

  • Wiring notes for feeding the speed signal into a PLC or logger

Delivery and after-sales

  • Stock in Shanghai, on-site demo and trial evaluation available

  • Selection advice, operator training and guidance on applying reflective tape

  • Factory warranty; reflective tape and other consumables stocked long term

Related reading: Tachometer range and selection points | Speed sensors: fixed-installation on-line measurement | Also see: Industrial test instruments overview

Previous:None

Back to list

Next:LUYOR-912 Intelligent Tachomet

Send inquiry

Message

  • Product Name:

  • Company:

  • Your Name:

  • Phone:

  • Email:

  • Province / Region:

  • Address:

  • Message:

Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447

SiteMap

Official WeChat QR code

WeChat QR
Official WeChat QR code Follow

Official WeChat QR code

Contact

131-2093-6518

Top