Xinysun Instrument (Shanghai) Co., Ltd.

Products

PRODUCTS

Breadcrumb Home > Products > Industrial Test Instruments > UV Radiometers

Labino Apollo 3.0 Wireless UV Radiometer
  • Labino Apollo 3.0 Wireless UV Radiometer

Labino Apollo 3.0 Wireless UV Radiometer

OverviewOverview

Apollo 3.0 sets a wireless UV-A probe up to 5 m from the readout: UV 0-50000 uW/cm2 at 4%, white 0-10000 lux at 3%, IP67 probe, ISO/IEC 17025 certificate.

Model:
Updated:2026-11-26
Manufacturer:
Reference price:Request a Quote
Views:
DetailsSend inquiry

Labino Apollo 3.0 separates the sensor from the readout over Bluetooth, so the probe stays where you put it and the number can be read from up to about 5 m away. That single change fixes the most common flaw in a UV-A check: the cable pulling the probe off the measurement point, or the operator crouching beside a hot lamp to read the display. UV channel 0-50,000 μW/cm² at ±4%, white channel 0-10,000 lux at ±3%, IP67 probe, and an ISO/IEC 17025 calibration certificate in the case.

Wireless Bluetoothprobe separate from the readout
Read from 5 mno cable pulling the sensor off the point
UV 0-50,000μW/cm² at ±4%, 300-400 nm
White 0-10,000lux at ±3%, 400-700 nm
IP67 probebattery change without recalibration
ISO/IEC 17025calibration certificate supplied

Why separating probe and readout changes the measurement

A conventional UV radiometer joins probe and body with a cable. In a laboratory that is fine. On site it is a liability: the cable's own weight tips the probe off the point, the cable is too short to read from anywhere comfortable, and a multi-point survey becomes five minutes of untangling and re-plugging for a one-minute job.

Apollo 3.0 puts the probe down and walks away with the readout, up to about 5 m. The practical gain is not convenience but consistency: once the probe is placed it does not move, so the geometry stays the same and the reading can be compared with the last one. That is exactly what a lamp-degradation trend needs. If the measurement position and angle shift slightly every time the cable is tugged, the series has no comparative value.

A second, quieter benefit is calibration without stopping work. With the two-sensor kit (M514) one probe goes away for its annual calibration while the other stays on the line.

The boundary to state clearly. Apollo 3.0 measures light; it does not change it. Its value comes from fixed points, fixed distance and a periodic record. One reading says what the lamp is doing now; the trend says whether it will still pass next quarter.

Three gains from a wireless probe

Fixed geometry, comparable numbers

  • The probe sits on the point without cable load

  • Distance and angle stay repeatable between shifts

  • Suits a lamp-intensity and calibration-interval trend record

  • No re-plugging when moving between points

A free reading position

  • Read at up to about 5 m, useful in darkrooms and at height

  • Red LED display, auto backlight in low light

  • Auto-ranging, so no range or unit selection

  • HOLD freezes a reading and PEAK captures the maximum, which helps when working alone

Measurement specification and stability

ChannelSpectral rangeSensitivity range (FWHM)RangeAccuracy
UV300-400 nm325-395 nm0-50,000 μW/cm²±4%
White light400-700 nm485-600 nm0-10,000 lux (1,000 fc)±3%

Both channels sit in one probe module and are displayed together, which is what a fluorescence check needs: enough UV, little enough ambient white light, both numbers from one placement.

On stability, the manufacturer's figure is a 0.1% drop after 30 minutes of continuous exposure at 50,000 μW/cm². Sensor fatigue of that order means a long survey or a continuous monitoring session does not drift, so readings taken an hour apart still belong to the same series. The white channel uses a bandpass filter set containing only non-fluorescent filters, which keeps visible leakage from the UV lamp itself out of the illuminance reading.

Which kit: M513, M514 or M515

KitContentsSuits
M513 (single sensor)One readout, one probe, case, calibration certificateA single station or line that can pause during calibration
M514 (two sensors)One readout, two probes, case, calibration certificatesScattered points, or work that cannot stop while one probe is away
M515 (probe only)Spare or additional probeAdding a probe later, or replacing one

The two-probe kit is the practical choice wherever calibration would otherwise mean an outage: send one probe, keep measuring with the other.

Operation and ownership

ItemDetail
Readout power3 × AA cells, about 100 hours
Probe power3 × AAA alkaline cells; the battery bay opens from outside, so no optical part is disturbed and no recalibration is needed
Probe ratingIP67, dust-tight and short-term immersion; the readout is not
StandardsNIST traceable design, stated against ISO 3059, with an ISO/IEC 17025 calibration certificate supplied
Warranty1 year, extended to 4 years when calibration is kept on the recommended schedule at an authorised laboratory
Calibration intervalAbout 6 months is the recommended starting point; adjust for use rate and customer requirements

If your acceptance document cites ASTM E3022 rather than ISO 3059, send us the clause and we will confirm the matching configuration before you order.

Frequently asked questions

Is a UV radiometer the same as a UV energy meter?

No. This instrument reads instantaneous irradiance in μW/cm²; a UV energy meter integrates dose in J/cm². Lamp acceptance uses irradiance, curing and crosslinking use dose.

How is Apollo 3.0 related to Apollo 2.0?

It is the replacement for Apollo 2.0, and the two generations do not share accessories or specifications. Only the 3.0 series (M513, M514, M515) is current and supported for calibration. Where documents mix 2.0 and 3.0 figures, treat the 3.0 data sheet as authoritative, or send us the clause to check.

Do I have to recalibrate after changing batteries?

No. The probe battery bay opens from outside, and the optical assembly is never touched, so a battery change does not disturb calibration.

What does the IP67 probe rating cover?

The probe is dust-tight and tolerates short-term immersion, which suits shop floors and outdoor work. The readout is not sealed to the same level: wipe it down and store it dry.

What do ±4% and ±3% refer to?

±4% is the accuracy of the UV channel across 0-50,000 μW/cm²; ±3% is the white channel across 0-10,000 lux. Both are referenced to NIST traceable standards, and the ISO/IEC 17025 certificate in the case supports audit and customer review.

Can both channels be read at once?

Yes. The UV and white sensors share one probe module, and the readout shows both, auto-ranged. A fluorescence check needs the two conditions verified together, so one placement gives both figures.

Is the display readable in a darkroom?

Yes. The readout uses a red LED display with automatic backlight in low light, and auto-ranging removes the need to select a range by feel. HOLD and PEAK cover single-person recording.

Why does the 30-minute, 0.1% figure matter?

It describes sensor fatigue. Some photodetectors drift noticeably under prolonged high-intensity UV, so the same lamp reads differently depending on how long the meter has been exposed. A 0.1% drop after 30 minutes at 50,000 μW/cm² means long surveys stay comparable.

How do I choose between Apollo 3.0, XP4000 and XRP-3000?

By the layout of the measurement points and how you want to read. XP4000 puts UV-A, white and 450 nm blue on one cabled head; XRP-3000 gives a body that accepts UV-C, UV-B, blue and luminance sensors; Apollo 3.0 gives a wireless probe readable from 5 m, which suits fixed points and darkrooms where you cannot stand next to the lamp.

How should a routine lamp check be run?

Fix distance, angle, lamp setting and points. Measure a new or freshly calibrated lamp for the baseline, then recheck on a schedule (quarterly, or every 500 hours) recording both UV and ambient white light. When the UV figure approaches the specified minimum, clean the filter, replace the lamp or send the meter in, rather than waiting for a detection failure.

All three meters are compared on the UV radiometer range page, and the selection logic behind the comparison is set out in how to choose a UV radiometer. Matching lamps: 365 nm black lights for PT and MT, and fluorescent leak detection for oil and water systems. Further reading: ten questions on inspection lamps.

Send inquiry

Message

  • Product Name:

  • Company:

  • Your Name:

  • Phone:

  • Email:

  • Province / Region:

  • Address:

  • Message:

Copyright 2026 Xinysun Instrument (Shanghai) Co., Ltd. All rights reserved.
ICP:ICP-2026046447

SiteMap | Privacy Policy | FAQ

Official WeChat QR code

WeChat QR
Official WeChat QR code Follow

Official WeChat QR code

Contact Contact

+86-131-2093-6518

Back to top Top