Overview
Threaded 303 stainless remote optical sensors with a visible red LED: 1-250,000 rpm, up to 0.9 m at 45 degrees, 3-15 Vdc supply, negative pulse output.
The ROS is a fixed-mount optical speed sensor, not a handheld tachometer. It shines a visible red LED at a reflective mark, returns one pulse per revolution, and hands that pulse train to a panel meter, PLC, recorder or stroboscope. Two termination styles cover almost every installation: the ROS-P ends in a 1/8 in (3.5 mm) stereo plug for instruments that have a socket, the ROS-W ends in three tinned leads for a terminal block. This page covers the range limits, the three ways to power the head, the green on-target LED that makes aiming a one-person job, and the full manufacturer specification.
Customers often treat these as two grades of sensor. They are not. The head is identical - same 303 stainless tube, same red LED, same 1-250,000 rpm range, same 0.9 m working distance, same 3.0-15 Vdc supply and the same negative pulse output. The only difference is what comes out of the cable end.
So the question is not which sensor is better, it is what your receiving equipment has: a terminal block or a socket.
| Decision point | ROS-W | ROS-P |
|---|---|---|
| Cable termination | Three tinned leads plus shield | 1/8 in (3.5 mm) male stereo plug |
| Receiving interface | Terminal block, PLC input module, panel meter terminals | Instrument or module with a 1/8 in jack |
| Typical partners | Monarch ACT series panel tachometers, F2A frequency-to-analog converters, DataChart DC6000 / DC1250 recorders | Monarch PLT200 handheld tachometer, Nova-Pro 300 / 500 stroboscopes, PLS Pocket LED Strobe, SPSR-IM power module |
| Power source | Panel meter, PLC or local DC supply, 3.0-15 V | Supplied by the instrument it plugs into, or by the SPSR-IM battery module |
| Fits when | There is a cabinet and the signal has to join a control or logging system | There is no cabinet, or the chain has to be portable and quick to set up |
| Model | Termination | Cable | Choose it when |
|---|---|---|---|
| ROS-W | Tinned leads | 8 ft (2.4 m) | Measurement point is within reach of the cabinet |
| ROS-P | 1/8 in plug | 8 ft (2.4 m) | Plugs into a handheld tachometer, stroboscope or SPSR-IM |
| ROS-W-25 | Tinned leads | 25 ft (7.6 m) | Large machine, or the cabinet sits across the aisle |
| ROS-P-25 | 1/8 in plug | 25 ft (7.6 m) | Portable measurement that needs a longer probe lead |
Every model ships with the sensor, its cable, a 90 degree mounting bracket, two M16 jam nuts and 12 in of T-5 reflective tape. Nothing else is needed to install it; the power and the receiving instrument are separate decisions.
The ROS is a probe, not an instrument. There is no cell inside and no display, so it needs an external 3.0-15 Vdc supply at about 40 mA before it will output anything. That single fact decides the rest of the bill of materials, so settle "where does the power come from and where does the signal go" before ordering.
One consequence is easy to miss: the pulse amplitude follows the supply. Feed the head 12 V and the output swings between 12 V and 0 V; feed it 5 V and the swing is 5 V. Match that to the input range of whatever is counting.
The simplest chain when a cabinet already exists. Monarch ACT series panel tachometers carry a sensor supply, so the three ROS-W leads land on the terminals marked for the sensor and nothing else is required. The same applies to the F2A frequency-to-analog converters and the DataChart recorders.
For a portable chain, plug a ROS-P into the SPSR-IM module. It runs from an internal NiMH pack, delivers more than 40 hours with a ROS-P connected, and outputs a TTL-compatible pulse on a BNC connector for a vibration analyser, spectrum analyser, data logger or recorder.
If a PLC already provides a 5 V or 12 V auxiliary output, the ROS-W can run straight from it. Confirm polarity and confirm that the counting input accepts a pulse of the same amplitude. Do not connect the head to 24 V - the ROS supply ceiling is 15 V. The 24 V option in this family is the ROLS24 laser model.
The ROS output is a negative pulse: the line idles at the supply voltage and drops to 0 V when the reflective mark passes. Many data acquisition systems, vibration analysers and PLC input cards count on a rising edge and will miss it. The INVERTED / NON-INVERTED switch on the SPSR-IM exists to flip that edge. Tell us the receiving instrument and we will confirm which position to use.
The rated working distance is 36 in (0.9 m) with up to 45 degrees of offset from the target normal. That is the shortest reach in the Monarch remote sensor family, and the reason is the light source: a visible red LED spreads its output, so the energy returning from a small reflective mark is weak compared with a laser. It works well up close and runs out of signal beyond about a metre.
Measure the distance from the mounting position to the rotating face before choosing anything. Under 0.9 m, the ROS is the economical answer. Over 1 m, no amount of aiming will recover the signal - move to the laser head.
| Light source | Models | Working distance | Off-angle | Notes |
|---|---|---|---|---|
| Visible red LED | ROS-W / ROS-P (this page) | 0.9 m (36 in) | 45 degrees | Lower cost, no laser controls, close-range single point |
| Modulated LED | ROSM-P / ROSM-W | 2.5 cm to 0.6 m | 45 degrees | Rejects ambient light; range narrows to 1-20,000 rpm |
| Visible red laser | ROLS-W / ROLS-P, ROLS-5PW | 7.6 m (25 ft) | 60 degrees | Long stand-off; Class 2 laser |
If the measurement point faces a roof light, a skylight or direct sun, an LED that runs continuously will pick up that light as noise. The ROSM switches the LED on and off at high frequency and only accepts the return at that frequency, so other sources are filtered out. The trade is range and speed: 1-20,000 rpm, 2.5 cm to 0.6 m, a 0 to +5 V positive pulse and a 5.0-24 Vdc supply. The body and the M16 thread are unchanged, so brackets and mounting practice carry over.
When the receiver sees the reflective mark, a green LED in the cable end cap lights. That turns alignment into something one person can do with no instrument connected: turn the shaft by hand, watch the end of the cable, and adjust the bracket until the lamp flickers cleanly with each pass of the mark. As speed rises the flicker blends into a steady glow.
It also gives a useful fault-isolation order. Lamp dark means the problem is in the light path or the tape, so do not start rewiring the meter. Lamp flickering but the display reads zero means the light path is fine and the fault is in the supply, the wiring or the edge setting at the receiving end.
The body is a 303 stainless tube threaded M16 x 1.5 and 74 mm long, supplied with two jam nuts and a 90 degree bracket. The nuts can lock anywhere along the thread, so the head can be clamped in the bracket for fine adjustment, or passed through a drilled plate and locked from both sides - which is often the only way into a cramped machine guard. The lens is acrylic: wipe it with a soft cloth when oil mist or dust builds up, and keep solvents away from it.
Use a rigid bracket on anything that vibrates. A magnetic base that creeps by a millimetre over a shift will walk the spot off the tape and the pulses will start dropping out at speed.
| Parameter | Specification |
|---|---|
| Product type | Fixed-mount non-contact optical speed sensor (visible red LED) |
| Models | ROS-W, ROS-P, ROS-W-25, ROS-P-25 (part number family 6180-057) |
| Speed range | 1-250,000 rpm |
| Illumination | Visible red LED |
| On-target indicator | Green LED in the cable end cap |
| Operating range | Up to 36 in (0.9 m) at up to 45 degrees offset from the target |
| Power required | 3.0-15 Vdc at 40 mA (external supply, no internal battery) |
| Output signal | Negative pulse, from the supply voltage (+V) down to 0 V |
| Connection | 1/8 in (3.5 mm) male stereo plug on ROS-P / ROS-P-25; tinned wires on ROS-W / ROS-W-25 |
| Cable length | 8 ft (2.4 m) standard; 25 ft (7.6 m) on the -25 models |
| Material | 303 stainless steel tube, mounting bracket and two M16 jam nuts |
| Lens | Acrylic |
| Dimensions | Threaded tube 2.90 in x 0.625 in diameter (M16 x 1.5 x 74 mm) |
| Operating temperature | -10 to 70 C (14 to 158 F) |
| Humidity | 80% RH maximum up to 31 C, decreasing linearly to 50% RH at 40 C |
| In the box | Sensor, cable, 90 degree bracket, two jam nuts, 12 in of T-5 reflective tape |
| Compatibility | ROS-P: PLT200, Nova-Pro 300 / 500, PLS Pocket LED Strobe. ROS-W: ACT series panel tachometers, F2A converters, DataChart DC6000 / DC1250 |
| Origin and compliance | Made in USA, CE marked, ECCN EAR99 |
Figures above are the manufacturer's published ratings. The 0.9 m figure is a maximum under good conditions - real reach depends on the tape, the angle and the ambient light, and can be shorter. No IP rating is published for this sensor, so it is not specified for washdown or condensing locations.
| Task | What the sensor does | Typical targets |
|---|---|---|
| Continuous condition monitoring | Feeds rpm to a panel tachometer with an over-speed alarm | Motors, fans, pumps, centrifuges, compressors, gearbox shafts |
| Vibration analysis | Provides the speed reference for order tracking and fault location | Test stand rotors, drivetrains, any rotating part analysed alongside a vibration channel |
| Stroboscopic inspection | ROS-P plugs into a stroboscope for speed-synchronised viewing | Blades, gears, belts, printing rollers, textile machinery |
| Line control | rpm as an interlock or feedback signal into a PLC | Conveyor rollers, pulleys, rotating stations |
| Test and development | Low-cost speed channel to log against other signals | Small motors, dental drills, drone rotors, model engines |
| Awkward locations | Head mounted at the machine, reading taken from a safe position | High-mounted equipment, dusty or noisy areas, guarded shafts |
External supply is mandatory: 3.0-15 Vdc at 40 mA, and never 24 V direct. Output amplitude tracks the supply, so confirm the receiving range. The output is a negative pulse, so check the edge your counter triggers on. There is no published IP rating, so keep the head out of washdown and condensation. The head cannot be repaired in the field - the optics and amplifier need calibration equipment. And measurement always needs a reflective mark: bare metal, even a polished shaft, will not produce a reliable pulse on its own.
The light source is an LED, not a laser, so no laser class label, no protective eyewear and no laser work procedure apply. It is still worth avoiding a direct look into the emitter while adjusting a bracket, and worth telling anyone else working on the machine where the beam points.
Decide by the receiving equipment, not by the sensor. If the signal lands on a terminal block, a panel meter or a PLC input module, take the ROS-W with its three tinned leads. If it plugs into a handheld tachometer, a stroboscope or an SPSR-IM module with a 1/8 in jack, take the ROS-P. Range, supply and output are identical.
A pulse train: one pulse per revolution. A meter, counter, PLC or converter turns frequency into rpm. If you want a number on a display without building that conversion yourself, pair the sensor with a panel tachometer such as the ACT series.
No. The ROS accepts 3.0-15 Vdc. If the cabinet only has 24 V, use a DC-DC converter or step down to 12 V, or choose the ROLS24 laser model which is built for 24 Vdc input.
Not directly in many cases. The ROS idles at the supply voltage and drops to 0 V at the mark, which is a falling edge. Either configure the input for falling-edge counting, add an inverter, or use the SPSR-IM module whose INVERTED switch outputs a positive-going pulse.
It confirms that the receiver is seeing the reflective mark. Adjust the bracket until it flickers once per revolution while turning the shaft by hand, and alignment is done without connecting a meter. At running speed it appears almost steady.
Because the source is an LED. Its output spreads, so the fraction of light returning from a small mark falls quickly with distance. A 650 nm laser keeps a tight spot at 25 ft. If the mounting point is more than about a metre from the shaft, plan on the laser head from the start.
The box contains the sensor, its cable, a 90 degree bracket, two M16 jam nuts and 12 in of T-5 reflective tape. You still need a 3.0-15 Vdc supply, the receiving instrument or PLC input, and spare tape for when the original mark wears or gets oiled.